ACTIVITY
PERMITS VALUATION
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
To correct violations issued by vieux carre comm Date: August 4, 2016Permit type: Vcc general work | Permit status: Application submitted | Current use: Mixed use | Permit id: 16-24850-Vcgen | |||||
To resolve outstanding vcc violations as follows:inspect and clean brick on first floor as necessary. No powerwashing permitted above 2 psi. The following methods are gentlest and should be considered first:a. Water with soft brushesb. Water with mild soapc. Water with stronger soapd. Water with stronger soap plus ammoniae. Water with stronger soap plus vinegarany further masonry work shall require separate vcc review, approval and permit. Remove existing plywood from interior of chartres and dumaine side first floor transom. Remove extraneous wiring on exterior. All conduit and wiring shall be placed along the inside corners of building surfaces as much as possible, such as along gallery balcony purlins at the deck line, and painted to match the adjacent surfaces. Remove all existing, unpermitted and or unshielded light fixturesinstall two (2) remcraft 1 fixtures to the underside of the gallery above the main doors on the dumaine and chartres elevations. All fixtures shall use lamps with Date: August 4, 2016Permit type: Vcc general work | Permit status: Permit issued | Expiration date: April 20, 2017 | Current use: Mixed use | Permit id: 16-24850-Vcgen |