Building Permits at 48 49 Block Of Rockwood Parkway Nw Washington DC


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with 48 49 Block Of Rockwood Parkway Nw Washington DC over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
SCORE
75
No excavation. Monitoring well exists. Monitoring well sampling. In the roadway of rockwood parkway to collect groundwater samples from multiport well, mp-5, located 5 feet se from lot 0901, square 1513 on behalf of us army corp of engineers in accordance with the ddoe approved work plan. Sampling is expected to be completed in one (1) day. Application is identical to previously approved construction permit 102996 (deposit so1043 on file).

Client: Us Army Corps Of Engineers Co Todd Beckwith | Permit type: Excavation; monitori | Permit id: Pa107390
2015/03/1607548 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Us Army Corp Of Engineers
Installation of one (1) flute multiport well, mp-5, in accordance with the ddoe approved work plan to assess/confirm the heretofore observed absence of groundwater perchlorate and arsenic contamination in this area. Mp-5 installation will require the closure of approximately 5 lf of rockwood pwky at the intersection of glenbrook road nw washington dc. The planned location for mp-5 is five (5) feet from the southeast portion of the center island on rockwood parkway at glenbrook rd nw, washington dc. In the road, 5 feet offset from se point of lot 0901, square 1513. A nominal 6-inch diameter surface casing will be set to top of competent rock and tremie-grouted into place. At least 12 hours will be allowed for the hydrated 60: bentonite-cement grout mixture [1 lbs of bentonite powder combined with 94 lbs cement; collectively hydrated with 82 gallons of water (3 lbs of dry solids to 1 gallon of water)] to set before drilling a nominal 6-inch diameter open bedrock bore hole to the completi
Date:  May 20, 2014

Client: Us Army Corps Of Engineers Co Todd Beckwith | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: September 25, 2014 | Permit id: Pa95726
2014/05/2009548 49 Block Of Rockwood Parkway Nw Washington Dc
No excavation. Monitoring well exists. Monitoring well sampling. In the roadway of rockwood parkway to collect groundwater samples from multiport well, mp-5, located 5 feet se from lot 0901, square 1513 on behalf of us army corp of engineers in accordance with the ddoe approved work plan. Sampling is expected to be completed in one (1) day. Application is identical to previously approved construction permit 102996 (deposit so1043 on file).
Date:  March 16, 2015

Client: Us Army Corps Of Engineers Co Todd Beckwith | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: June 11, 2015 | Permit id: Pa107390
2015/03/1609548 49 Block Of Rockwood Parkway Nw Washington Dc
Installation of one (1) flute multiport well, mp-5, in accordance with the ddoe approved work plan to assess/confirm the heretofore observed absence of groundwater perchlorate and arsenic contamination in this area. Mp-5 installation will require the closure of approximately 5 lf of rockwood pwky at the intersection of glenbrook road nw washington dc. The planned location for mp-5 is five (5) feet from the southeast portion of the center island on rockwood parkway at glenbrook rd nw, washington dc. In the road, 5 feet offset from se point of lot 0901, square 1513. A nominal 6-inch diameter surface casing will be set to top of competent rock and tremie-grouted into place. At least 12 hours will be allowed for the hydrated 60: bentonite-cement grout mixture [1 lbs of bentonite powder combined with 94 lbs cement; collectively hydrated with 82 gallons of water (3 lbs of dry solids to 1 gallon of water)] to set before drilling a nominal 6-inch diameter open bedrock bore hole to the completi
Date:  May 20, 2014

Client: Us Army Corps Of Engineers Co Todd Beckwith | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: September 25, 2014 | Permit id: Pa95726
2014/05/2009548 49 Block Of Rockwood Parkway Nw Washington Dc
No excavation. Monitoring well exists. Monitoring well sampling. In the roadway of rockwood parkway to collect groundwater samples from multiport well, mp-5, located 5 feet se from lot 0901, square 1513 on behalf of us army corp of engineers in accordance with the ddoe approved work plan. Sampling is expected to be completed in one (1) day. Application is identical to previously approved construction permit 102996 (deposit so1043 on file).
Date:  March 16, 2015

Client: Us Army Corps Of Engineers Co Todd Beckwith | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: June 11, 2015 | Permit id: Pa107390
2015/03/1609548 49 Block Of Rockwood Parkway Nw Washington Dc
SCORE
67
Construction staging area
Date:  December 17, 2014

Permit status: Expired | Expiration date: February 3, 2015 | Permit id: Pa10171149
2014/12/1706748 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Us Army Corps Of Engineers
SCORE
89
Enp for ddot contractors
Date:  May 13, 2016
Contractor: Delante Toyer

Permit status: Expired | Expiration date: June 3, 2016 | Permit id: Pa10274307
2016/05/1308948 49 Block Of Rockwood Parkway Nw Washington DcDelante Toyer
SCORE
100
Enp for ddot contractors
Date:  June 2, 2016

Permit status: Expired | Expiration date: June 27, 2016 | Permit id: Pa10287621
2016/06/02010048 49 Block Of Rockwood Parkway Nw Washington DcFort Myer Construction Corp
SCORE
67
Installation of one (1) flute multiport well, mp-5, in accordance with the ddoe approved work plan to assess confirm the heretofore observed absence of groundwater perchlorate and arsenic contamination in this area. Mp-5 installation will require the closure of approximately 5 lf of rockwood pwky at the intersection of glenbrook road nw washington dc. The planned location for mp-5 is five (5) feet from the southeast portion of the center island on rockwood parkway at glenbrook rd nw, washington dc. In the road, 5 feet offset from se point of lot 0901, square 1513. A nominal 6-inch diameter surface casing will be set to top of competent rock and tremie-grouted into place. At least 12 hours will be allowed for the hydrated 60: bentonite-cement grout mixture [1 lbs of bentonite powder combined with 94 lbs cement; collectively hydrated with 82 gallons of water (3 lbs of dry solids to 1 gallon of water)] to set before drilling a nominal 6-inch diameter open bedrock bore hole to the completi
Date:  July 11, 2014

Permit status: Permit expired | Expiration date: September 25, 2014 | Permit id: Pa95726
2014/07/1106748 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Usace
SCORE
67
No excavation. Monitoring well exists. Monitoring well sampling. In the roadway of rockwood parkway to collect groundwater samples from multiport well, mp-5, located 5 feet se from lot 0901, square 1513 on behalf of us army corp of engineers in accordance with the ddoe approved work plan. Sampling is expected to be completed in one (1) day. Application is identical to previously approved construction permit 102996 (deposit so1043 on file).
Date:  April 3, 2015

Permit status: Permit expired | Expiration date: June 11, 2015 | Permit id: Pa107390
2015/04/0306748 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Usace
SCORE
75
Installation of one (1) flute multiport well, mp-5, in accordance with the ddoe approved work plan to assess confirm the heretofore observed absence of groundwater perchlorate and arsenic contamination in this area. Mp-5 installation will require the closure of approximately 5 lf of rockwood pwky at the intersection of glenbrook road nw washington dc. The planned location for mp-5 is five (5) feet from the southeast portion of the center island on rockwood parkway at glenbrook rd nw, washington dc. In the road, 5 feet offset from se point of lot 0901, square 1513. A nominal 6-inch diameter surface casing will be set to top of competent rock and tremie-grouted into place. At least 12 hours will be allowed for the hydrated 60: bentonite-cement grout mixture [1 lbs of bentonite powder combined with 94 lbs cement; collectively hydrated with 82 gallons of water (3 lbs of dry solids to 1 gallon of water)] to set before drilling a nominal 6-inch diameter open bedrock bore hole to the completi

Client: Us Army Corps Of Engineers C O Todd Beckwith | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: September 25, 2014 | Permit id: Pa95726
2014/05/2007548 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Us Army Corp Of Engineers
SCORE
75
No excavation. Monitoring well exists. Monitoring well sampling. In the roadway of rockwood parkway to collect groundwater samples from multiport well, mp-5, located 5 feet se from lot 0901, square 1513 on behalf of us army corp of engineers in accordance with the ddoe approved work plan. Sampling is expected to be completed in one (1) day. Application is identical to previously approved construction permit 102996 (deposit so1043 on file).

Client: Us Army Corps Of Engineers C O Todd Beckwith | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: June 11, 2015 | Permit id: Pa107390
2015/03/1607548 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Us Army Corp Of Engineers
SCORE
95
Construction staging area

Permit status: Resubmit | Expiration date: August 16, 2017 | Permit id: 0
09548 49 Block Of Rockwood Parkway Nw Washington DcWash Gas And Light Co
SCORE
67
Construction staging area

Permit status: Permit expired | Expiration date: September 9, 2014 | Permit id: Pa10149655
2014/08/1206748 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Us Army Corps Of Engineers
SCORE
67
Construction staging area

Permit status: Permit expired | Expiration date: June 30, 2015 | Permit id: Pa10183364
2015/06/0506748 49 Block Of Rockwood Parkway Nw Washington DcUrs Corporation On Behalf Of Us Army Corps Of Engineers
SCORE
100
Construction staging area
Date:  September 20, 2016
Contractor: Washington Gas

Permit status: Permit expired | Expiration date: October 20, 2016 | Permit id: Pa10347171
2016/09/20010048 49 Block Of Rockwood Parkway Nw Washington DcWashington Gas
SCORE
95
Construction staging area

Permit status: Resubmit | Expiration date: August 16, 2017 | Permit id: 0
09548 49 Block Of Rockwood Parkway Nw Washington DcWash Gas And Light Co
BEST LOCAL CONTRACTORS




Contractor Rank Contractor Details Number of Projects Avg. Project Cost Years in Business Photos
Need a Contractor ?
Just fill out a form below and get several free quotes from best local contractors in your area.