| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
New commercial construction - shell & core building a-permit extended until 11/10/2013 Date: May 10, 2012 Value: $7,000,000Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 582551 | |||||
2 comm awings Date: August 5, 2013 Value: $4,800Permit type: Commercial building | Permit status: Stop work | Current use: Restaurant | Permit id: 640369 | |||||
Revision 5/3/13 architectual & mechanical only revision issued on 5/14/2013 Date: April 19, 2013 Value: $682,000Permit type: Commercial building | Permit status: Issued | Current use: Restaurant | Permit id: 616275 | |||||
Two story parking garage revision 1/18/12 - architectural, electrical, mechanical, & structural; no change to estimated cost revision issued on 3/27/2012 Date: December 22, 2011 Value: $5,150,000Permit type: Commercial building | Permit status: Issued | Current use: Garage | Permit id: 581963 | |||||
Canopy over a patio Date: October 1, 2013 Value: $24,000Permit type: Commercial building | Permit status: Finaled | Current use: Restaurant | Permit id: 644755 | |||||
Construction of wegmans food market revision #1submitted 1/10/13. Estimated project cost for this revision #1is 50,000. 00. Revision issued on 2/6/2013 revision #2 submitted on 04/09/13 -structural & architectural. Estimated cost for revision is 40,0 no change in sq ft. (emc). Base permit fee for revision #2 on the submitted estimated project cost of 40,000. 00. Revision #2 issued 5/23/13 Date: July 17, 2012 Value: $16,915,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 594146 | |||||
First time tenant-family dental associates - suite #212 Date: February 11, 2014 Value: $141,000Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 661697 | |||||
New commercial construction - shell & core building c-permit extended until 11/10/2013 Date: May 10, 2012 Value: $1,250,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 582552 | |||||
New commercial construction - shell & core building d-permit extended until 11/10/2013 Date: May 10, 2012 Value: $1,250,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 582553 | |||||
New tenant fit out / 1st time tenant / 267 occupants per drawings u/o# 291825 revision 8/5/13 revision of 8/5/13 was reviewed as not increasing the estimated project cost. Charge a minimum permit fee for this revision permit. Occupant load changed from 267 to 268. Revision issued on 8/21/2013 revision - 10/4/13 - arch changes/ 5423 square feet / 60 cost per application use 60 for the cost of the revision of 10/4/13 Date: July 16, 2013 Value: $600,000Permit type: Commercial building | Permit status: Issued | Current use: Restaurant | Permit id: 631951 | |||||
Landlord improvements suite d-3 u/o #305006 Date: December 28, 2012 Value: $50,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 613240 | |||||
New tenant fit out for restaurant revision - 3/22/13 - elec, mech, arch changes for 2127 sq feet occupant load 91 interior seating and staff occupant load 16 exterior patio seating total occupant load 117 revision #2 submitted on 6/6/13 - architectural - no change in sq ft or cost (emc) Date: January 30, 2013Permit type: Commercial building | Permit status: Issued | Current use: Restaurant | Permit id: 613525 | |||||
Landlord improvements suite c-4 Date: November 14, 2012 Value: $25,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 614167 | |||||
Landlord improvements suite c-3 Date: November 14, 2012 Value: $23,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 614170 | |||||
Landlord improvements suite d-4 Date: November 14, 2012 Value: $15,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 614171 | |||||
Interior tenant fit out ste-a-8 revision #2 - submitted 9/11/13 - architectural, electrical, mechanical & fire - no change in sq ft or cost.. Requesting expedited review.. Date: January 15, 2013 Value: $60,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 615803 | |||||
Interior tenant fit out Date: February 5, 2013 Value: $20,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 615799 | |||||
Tenant fit out bubbles hair salon space d-3 Date: March 18, 2013 Value: $156,900Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 617577 | |||||
Tenant fit out the hair cuttery suite a-12 u/o 283762 Date: March 18, 2013 Value: $82,500Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 617580 | |||||
Revision - 3/20/13 - elec, mech, arch, kitchen - Date: March 20, 2013 Value: $125,000Permit type: Commercial building | Permit status: Issued | Current use: Assembly building | Permit id: 619401 | |||||
Interior renovations revision - 3/20/13 - mechanical, architectural changes/ expedited / Date: March 7, 2013 Value: $30,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 621010 | |||||
First time tenant / tenant fit out Date: May 22, 2013 Value: $125,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 624961 | |||||
Interior alterations space a-2 Date: April 9, 2013 Value: $85,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 627917 | |||||
First time tenant Date: April 25, 2013 Value: $40,000Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 628057 | |||||
Interior tenant fit out 1st tenant with outside seating revision submitted on 7/22/13 - electrical - no change in cost or sq ft. (emc) Date: June 6, 2013 Value: $490,000Permit type: Commercial building | Permit status: Issued | Current use: Restaurant | Permit id: 629958 | |||||
Tenant fit out / yogurt shop / first time tenant Date: March 27, 2014 Value: $40,000Permit type: Commercial building | Permit status: Finaled | Current use: Restaurant | Permit id: 630345 | |||||
Commercial building Date: June 20, 2013 Value: $45,000Permit status: Finaled | Current use: Mercantile building | Permit id: 631125 | |||||
First time tenant Date: June 17, 2013 Value: $65,000Permit type: Commercial building | Permit status: Finaled | Current use: Assembly building | Permit id: 633118 | |||||
Commercial building Date: December 13, 2012 Value: $925,000Permit status: Issued | Current use: Assembly building | Permit id: 605652 | |||||
Valet - suite a-11 u/o #279249 Date: September 7, 2012 Value: $55,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 609639 | |||||
Commercial building Date: December 13, 2012 Value: $1,200,000Permit status: Issued | Current use: Assembly building | Permit id: 611787 | |||||
Interior alteration to vacant space / suite d-1 Date: December 31, 2012 Value: $50,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 619222 | |||||
Landlord improvement Date: January 11, 2013 Value: $30,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 622004 | |||||
Tenant fit-out Value: $125,000Permit type: Commercial building | Permit status: Open | Current use: Mercantile building | Permit id: 624680 | |||||
First time tenant space Date: July 24, 2013 Value: $900,000Permit type: Commercial building | Permit status: Issued | Current use: Business building | Permit id: 633105 | |||||
Modification to existing tenant space Date: September 19, 2013 Value: $100,000Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 643641 | |||||
New tenant fit out Date: September 16, 2013 Value: $90,000Permit type: Commercial building | Permit status: Finaled | Current use: Mercantile building | Permit id: 647467 | |||||
Animal hospital Date: January 6, 2014 Value: $100,000Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 655715 | |||||
New const. Date: August 27, 2014 Value: $750,000Permit type: Commercial building | Permit status: Finaled | Current use: Bank | Permit id: 669649 | |||||
Tenant fit out - 2nd floor suite #217 Date: July 23, 2015 Value: $85,000Permit type: Commercial building | Permit status: Finaled | Current use: Business building | Permit id: 716980 | |||||
New tenant fit out for dental office Date: January 27, 2016 Value: $60,000Permit type: Commercial building | Permit status: Issued | Current use: Business building | Permit id: 733754 | |||||
Interior tenant fit out Value: $20,000Permit type: Commercial building | Permit status: Open | Current use: Business building | Permit id: 744917 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Smashburger - the shops @ seneca meadows suite d1- ap #613525 u&o #281273 200amp 480/277v disconnect & feeder from electric room to 200amp mcb panel dp 45kva transformer, 150amp 120/208v panel p1, 100amp subpanel l1, rtu 1, 2 & 3, hood & mau, freezer & cooler--revision 3/22/13-rlc no change in fee Date: June 27, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Restaurant | Permit id: 619911 | |||||
The shops @ seneca meadows suite d-1 landlord improvements - ap #619222 install 400amp meter & 400amp breaker enclosure in electrical room for space d-1 install conduit to space-tentant to complete on ap #613525/ elect #619911 ( smashburger ) Date: August 13, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Mercantile building | Permit id: 621210 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Please do not request inspections under this permit until 2 business days after permit issuance. Littkle seneca animal hospital space e4 - ap #655715 u&o not known 200amp 277/480v disconnect & meter on trough, 200amp feeder to panel he4, 45kva transformer, 150amp mcb panel pe4, 2-rtu Date: February 26, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 656394 | |||||
2- illuminated wall signs: sign permit:679321/326; 10-13-2014 - processed, mailed to: vu tran - 10999 red run blvd, owings mills, md 21117; copy sent to imaging on this date. Date: October 13, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 679318 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Please do not request inspections under this permit until 2 business days after permit issuance. Famous daves germantown fit out - blg b - ap #616275 (u&o 277246 on shell blg ap #605652) panels b & b1 , c 225 amp, panel c & ig 125amp, mua, hood fans, beer cooler, cooler & freezer, chiller Date: June 13, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Restaurant | Permit id: 628231 | |||||
And 206 seneca meadows parkway Date: October 26, 2011Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 583091 | |||||
Electrical permit Date: October 26, 2011Permit status: Finaled | Current use: Business building | Permit id: 583092 | |||||
The shops @ seneca meadow parking garage-ap #581963 u&o # 271619 2 story garage for wegmans store 600amp 277/480v service,20kw inverter,2 40hp elevators,20hp cart lift, split system a/c 6hp,exhaust fan 1/4hp,16 site lights Date: March 19, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Garage | Permit id: 587114 | |||||
The shops @ seneca meadows -ap #582551 u&o #271702 building a core & shell only 4000amp 277/4 v service w/ six 8 amp mains msba,800amp panel hdpp, hdp 1 & 2,elevator 40hp,rtu1 64hp,rtu2 & 5 23hp,rtu 3 39hp,rtu 4 51hp, 8hp split system,26 site lights Date: September 24, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 593278 | |||||
The shops @ seneca meadows -ap #582552 u&o #271703 building c core & shell only-no rtus 800amp 277/4 v service main,trough to future tenant meters,100amp house meter & panel hcp ,15kva transformer, amp panel pcp ,47 site lights Date: September 24, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 593279 | |||||
Temp for construction Date: April 30, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 597484 | |||||
Construction trailer use & acc#274241 Date: May 18, 2012Permit type: Electrical permit | Permit status: Issued | Current use: Trailer | Permit id: 599512 | |||||
Electrical permit Date: July 9, 2012Permit status: Finaled | Current use: Business building | Permit id: 604225 | |||||
Wegmans store germantown-ap #594146 Date: August 17, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 608127 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Date: October 4, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 611658 | |||||
Light poles; this permit is the child of permit: 582551 which expires: 11-10-2013(jr) Date: September 24, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 612660 | |||||
The shops @ seneca meadows suite d-4 landlord improvements - ap #614171 install 200amp meter & 200ampdisconnect in electrical room for space d-4 (volavie) feeder on fit up permit Date: August 13, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 616944 | |||||
The shops @ seneca meadows suite c-3 landlord improvements - ap #6141 install 200amp meter & 200ampdisconnect in electrical room for space c-3 (bella nails) feeder to space on fit up permit Date: August 13, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 617733 | |||||
1-2 amp feeder. Date: August 13, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 617732 | |||||
The shops @ seneca meadows building b core & shell -ap #605652 u&o #277246 for famous daves -fit out on ap #616275 / electric #628231 600amp 277/4 volt service, 600amp mcb panel hdpb , 112. 5kva transformer, 400amp mcb panel pdpb , 2 -rtu Date: June 27, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Restaurant | Permit id: 617965 | |||||
The shops at seneca meadows: note: no roof top hvac units shown on this plan./ core & shell Date: April 10, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 618039 | |||||
Electrical permit Date: June 6, 2013Permit status: Finaled | Current use: Business building | Permit id: 621353 | |||||
Low voltage only Date: December 20, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 621596 | |||||
Burgular alarm Date: December 20, 2012Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 621597 | |||||
1 4 amp disconnect Permit type: Electrical permit | Permit status: Open | Current use: Business building | Permit id: 622645 | |||||
Two cus, 7/ h. P. Each; 200amp; 100amp panel; 30kva transformer Permit type: Electrical permit | Permit status: Open | Current use: Mercantile building | Permit id: 622685 | |||||
Low voltage only Date: January 30, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Business building | Permit id: 624793 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Bldg permit#615799: landlord improvements: 45 kva transformer, two rooftop cvs, 8 9/10h. P. Each, 125amp panel, 200amp panel, 100amp feeder from electrical room to the tenant space Date: June 19, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Mercantile building | Permit id: 625298 | |||||
Wiring for motors only. Date: February 25, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Business building | Permit id: 626841 | |||||
6- illuminated wall signs: sign permit:627190/91/92/93/94/95 Date: April 15, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 627189 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Shops @ seneca meadows landlord improvements space a2 - ap #627917 for montgomery county liquor store 200amp 277/480v disconnect & meter from fused trough, feeder to space, 200amp mlo panel ha2, 45kva transformer, 150amp mcb panel pa2 5-cu units, 5-gas furnaces Date: June 19, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 629126 | |||||
2- illuminated wall signs: sign permit:630866;68 Date: April 25, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 630864 | |||||
Volavie frozen yorgurt d-4 - ap #630345 u&o #290942 200amp 277/480v meter & disconnect, feeder to 2 amp panel h, 75kva transformer, 225amp 120/208v panel l, rtu 1 Date: April 21, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Restaurant | Permit id: 630906 | |||||
Additional equipment: 1-125 amp disc;75kva transformer;225 amp panel,22kkw rtu. Date: June 18, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Business building | Permit id: 631409 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Floormax suite c-4 -ap #624961 u&o #287619 shops at seneca meadows suite c-4 Date: August 5, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Mercantile building | Permit id: 631845 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Little gym suite a 9 - ap #633118 u&o not known 200amp 277/480vdisconnect & meter on trough, 200amp panel ha9 30kva transformer, 100amp mcb panel pa9 , cu 1-3 Date: June 21, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Assembly building | Permit id: 633420 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Additional equipment: 1-2 amp disconnect; 1-2 amp panel, 1-45 kva transformer, 1-1 amp panel, 1-12 kw rtu Date: June 26, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 636325 | |||||
Revision changed service size from 600amp to 400amp 8-1-13 new 6 amp service- additional equipment: 4- sub-panels. 1- > 75 hp transformer, 2-> hp rtus; low votlage for telephone & pos, 8- appliances - panera bread. Date: June 19, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Restaurant | Permit id: 639071 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Interior tenant fit out: additional equipment: 1- kva transformer, 2-2 amp panel, 1-1 amp panel. Date: July 3, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 640738 | |||||
Meter pedestel located on ne corner of intersection entrance to shops @ seneca hwy new 100amp meter pedestal for traffic signal (new service approved by mr. Waclawski) Date: July 11, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Commercial miscellaneous struc | Permit id: 641637 | |||||
Sign permit #642310 Date: September 10, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 642311 | |||||
Sign permit #642313 Date: September 10, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 642314 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Suite 210 Date: September 17, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 642356 | |||||
2- illuminated wall signs:sign permit:642486;488 Date: August 29, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 642485 | |||||
Music & speaker system Date: July 31, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Business building | Permit id: 643881 | |||||
2- illuminated wall signs: sign permit:644394/644397 Date: September 11, 2013Permit type: Electrical permit | Permit status: Issued | Current use: Illuminated sign | Permit id: 644390 | |||||
Sign permit #644865--- s18464 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644866 | |||||
Concept sign permit #644890- tag #s-18466 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644892 | |||||
Crest cleaners suite a- - ap #643641 u&o #298083 400amp meter & disconnect on trough, 400amp feeder to space & panel ha10, 112. 5kva transformer, 400amp 2 section panel pa a & b, vacuum, air compressor, chiller & pumps, hpu, exhaust fan Date: September 23, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 645406 | |||||
Low voltage for voice, data and cabling only Date: August 20, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 646136 | |||||
Electrical permit Permit status: Open | Current use: Business building | Permit id: 646609 | |||||
3 illuminated sign on bldg wall la tagliatella .. Tag id#s-18476, s-18477, s-18478 Date: November 18, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 646915 | |||||
Seneca meadows beer & wine space d-2 - ap #647467 u&o #300464 200amp disconnect & meter, 200amp feeder to panel hd2, 75 kva transformer, 225amp mcb panel ld2 rtu, 2 cooler condensers Date: October 14, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 648120 | |||||
Illuminated sign on bldg wall smashburger tag#s-184 & tag#s-18491--sign concept plan Date: June 20, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 648677 | |||||
Illuminated sign on bldg wall-- the mattress professionals tag#s-16285--sign concept Date: October 24, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 650592 | |||||
Illuminated sign: sign permit:654793 Date: December 6, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 654783 | |||||
2- illuminated wall signs: sign permit:655005,08 Date: December 6, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 655003 | |||||
Commercial alteration - animal hospital - low voltage only for voice/data Date: December 6, 2013Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 657306 | |||||
Family dental associates suite #212 - ap #661697 70amp 277/480v fedder to space, panel ht2-2, 45kva transformer, panel pt2-2, 6 dental chairs, 4 x ray arms, 1 pan x ray, air commpressor & vacuum Date: March 11, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 662210 | |||||
Illuminated wall sign: sign permit: 663411 Date: May 19, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 663414 | |||||
Illuminated wall sign: sign permit:666076 Date: April 24, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 666075 | |||||
Electrical permit Date: March 27, 2014Permit status: Finaled | Current use: Business building | Permit id: 667282 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Date: June 2, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Bank | Permit id: 674969 | |||||
Bank of america-seneca meadows- ap #669649 u&o # not known 4 amp 120/208 volt service, rtu 1-5 Date: September 9, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Bank | Permit id: 675885 | |||||
4- illuminated signs: sign permit:676959/962/955/956: 09-30-2014- processed, picked up, sent to imaging on this date. Date: September 30, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Illuminated sign | Permit id: 676947 | |||||
Low voltage Date: December 4, 2014Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 696746 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Date: July 23, 2015Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 721388 | |||||
Illuminated wall signs: sign permit: 730213;730226 ; 10-15-2015 - processed, mailed to: ark sign services, inc - 3622 east street, hyattsville, md 20785 ; copy sent to imaging on this date. Date: October 15, 2015Permit type: Electrical permit | Permit status: Issued | Current use: Illuminated sign | Permit id: 730208 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Date: January 28, 2016Permit type: Electrical permit | Permit status: Finaled | Current use: Business building | Permit id: 737370 | |||||
Electrical permit Permit status: Open | Current use: Business building | Permit id: 747360 | |||||
Hvac modifications per submittal & approved plans under permit #627917 Date: April 15, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 631609 | |||||
New commercial building - heating equipment, ductwork, roof exhaust fan louver and damper Date: December 3, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 656848 | |||||
Refrigeration only- heating and cooling not included in this permit as approved by mr. Toschi Date: September 26, 2012Permit type: Mechanical permit | Permit status: Issued | Current use: Mercantile building | Permit id: 612802 | |||||
Ductwork not included in this permit. Date: March 13, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 628414 | |||||
Hvac modifications per submitted & approved plans under permit number #621010 Date: April 15, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 631607 | |||||
Note: walk in coolers not included in this permit Date: May 2, 2013Permit type: Mechanical permit | Permit status: Issued | Current use: Restaurant | Permit id: 633613 | |||||
New mechanical equipment Date: August 14, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 645443 | |||||
Ductwork only Date: September 26, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Mercantile building | Permit id: 649870 | |||||
Also installing walk-in with refrigeration equipment Date: September 27, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 649976 | |||||
New commercial construction - heating/cooling equipment & ductwork Date: October 30, 2014Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 693160 | |||||
Tenant fit out - 2nd floor suite #217 - ductwork - (3) vav boxes & 1 each exhaust fan Date: July 29, 2015Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 722205 | |||||
Existing commercial - suite 218 - new registers and grillles for tenant fit out & exhaust fans Date: February 2, 2016Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 743412 | |||||
Piping to equipment not included in this permit. Date: February 15, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 626347 | |||||
Refrigeration piping for walk-in cooler and two ice machines. Condensers located on roof of building Date: July 8, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 641048 | |||||
Note 11/05/2013 - permit initially entered as 206 seneca meadows pkw bldg e. - however has been amended to reflect parent building permit #631951 correct address 206 seneca meadows pkw bldg. E Date: August 23, 2013Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 646527 | |||||
Tenant fit out / yogurt shop / first time tenant - heating/cooling equipment, ductwork, piping of equipment Date: April 21, 2014Permit type: Mechanical permit | Permit status: Finaled | Current use: Business building | Permit id: 670050 | |||||
Tenant fit-out Value: $125,000Permit type: Commercial building | Permit status: Open | Current use: Mercantile building | Permit id: 624680 | |||||
Interior tenant fit out Value: $20,000Permit type: Commercial building | Permit status: Open | Current use: Business building | Permit id: 744917 | |||||
1 4 amp disconnect Permit type: Electrical permit | Permit status: Open | Current use: Business building | Permit id: 622645 | |||||
Two cus, 7/ h. P. Each; 200amp; 100amp panel; 30kva transformer Permit type: Electrical permit | Permit status: Open | Current use: Mercantile building | Permit id: 622685 | |||||
Sign permit #644865--- s18464 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644866 | |||||
Concept sign permit #644890- tag #s-18466 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644892 | |||||
Electrical permit Permit status: Open | Current use: Business building | Permit id: 646609 | |||||
Electrical permit Permit status: Open | Current use: Business building | Permit id: 747360 | |||||
1 4 amp disconnect Permit type: Electrical permit | Permit status: Open | Current use: Business building | Permit id: 622645 | |||||
Two cus, 7/ h. P. Each; 200amp; 100amp panel; 30kva transformer Permit type: Electrical permit | Permit status: Open | Current use: Mercantile building | Permit id: 622685 | |||||
Electrical permit Permit status: Open | Current use: Business building | Permit id: 747360 | |||||
Sign permit #644865--- s18464 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644866 | |||||
Concept sign permit #644890- tag #s-18466 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644892 | |||||
Electrical permit Permit status: Open | Current use: Business building | Permit id: 646609 | |||||
Tenant fit-out Value: $125,000Permit type: Commercial building | Permit status: Open | Current use: Mercantile building | Permit id: 624680 | |||||
Interior tenant fit out Value: $20,000Permit type: Commercial building | Permit status: Open | Current use: Business building | Permit id: 744917 | |||||
Restoration of row complete repair (restoration of right of way) shall be made of any and all damages done to the existing improvements in the public right of way caused byconstruction operations. Work shall be complete as directed by the dps row inspector and in accordance with the public right-of-way accessibility guidelines (prowag). All lane and sidewalk closures/traffic controls shall comply with the mcdot approved traffic control plans, work zone temporary traffic control standards and directions of the dps row inspector. (maryland dnr permit is required prior to remove/impact street trees. Complete tree protection and replanting per mc dps approved tree protection plan.) Date: August 8, 2014Permit type: Public right of way | Permit status: Completed | Current use: Driveway | Permit id: 319466 | |||||
Fire hydrant: construct fire hydrant and water connection in accordance with wssc plans and specifications. Work shall comply with ada requirements, montgomery county specifications for utility construction permit and the direction of the dps inspector. A mill and overlay shall be required should the patch not meet the specifications as set forth by the current county specifications for utility construction permit and as directed by the dps row inspector. All lane closures and traffic controls shall comply with the mcdot approved traffic control plans, work zone temporary traffic control standards and directions of the dps row inspector. Date: November 4, 2011Permit type: Public right of way | Permit status: Completed | Current use: Public utility | Permit id: 271649 | |||||
Two cus, 7/ h. P. Each; 200amp; 100amp panel; 30kva transformer Permit type: Electrical permit | Permit status: Open | Current use: Mercantile building | Permit id: 622685 | |||||
1 4 amp disconnect Permit type: Electrical permit | Permit status: Open | Current use: Business building | Permit id: 622645 | |||||
Electrical permit Permit status: Open | Current use: Business building | Permit id: 646609 | |||||
Illuminated wall sign on building ;sig tag s-19022sign permit 7781767 postal place Date: November 3, 2016Permit type: Electrical permit | Permit status: Issued | Current use: Illuminated sign | Permit id: 778176 | |||||
Interior tenant fit out. Cost of construction has been revised to 50,000. 00 Date: September 6, 2016 Value: $20,000Permit type: Commercial building | Permit status: Issued | Current use: Business building | Permit id: 744917 | |||||
Tenant fit-out Value: $125,000Permit type: Commercial building | Permit status: Open | Current use: Mercantile building | Permit id: 624680 | |||||
Please do not request inspections under this permit until 2 business days after permit issuance. Postal place Date: October 10, 2016Permit type: Electrical permit | Permit status: Issued | Current use: Business building | Permit id: 768797 | |||||
Sign permit #644865--- s18464 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644866 | |||||
Concept sign permit #644890- tag #s-18466 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 644892 | |||||
Install backhaul transport equipment on the existing light pole in the right-of-way. Mobilitie has a franchise agreement with montgomery county to work in the row. Note:regarding cell tower committee and zoning denied. Permit type: Public right of way | Permit status: Open | Current use: Public utility | Permit id: 352685 | |||||
Iiluminated wall sign on building sign tag #s-19027 mattress firm sign permit 780900 Permit type: Electrical permit | Permit status: Open | Current use: Illuminated sign | Permit id: 780902 | |||||
Tenant fit out--space a-11 postal place Date: August 23, 2016 Value: $25,000Permit type: Commercial building | Permit status: Issued | Current use: Mercantile building | Permit id: 762629 | |||||
Wall mounted signs: sign permits: 770987/770991 ; 09-08-2016 - processed, mailed to: sterico signs : 16159 shady grove road, gaithersburg, md 20877 ; copy sent to imaging on this date. Date: September 8, 2016Permit type: Electrical permit | Permit status: Issued | Current use: Illuminated sign | Permit id: 770981 |