| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Temporary power service - (6) 2 amps or less, (1) 401-600, (30) branch circuits, (1) limited energy for phone Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: December 30, 2014 | Permit id: 2014-254993-000 | |||||
Groundwork plumbing through 1st floor Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104026-000 | |||||
Sanitary only, 1 of 2: contractor to install mh and build lateral for connection to 8in csp sani-only public sewer main line in sw moody, approx depth 15. 8ft. Contractor verify depth/location in the field, follow city details p262, p150. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104147-000 | |||||
Storm only 1 of 2: contractor to install mh, build lateral to property. Mh to be located in sw moody, 12in csp public storm main line, approx depth 17ft, contractor confirm depth/location in the field, follow city details p262/p150. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104177-000 | |||||
Sanitary only, 2 of 2: contractor to make connection to public branch from mh abu855 in sw river dr. Main line is 10in ncp approx depth 12. 3ft, branch approx 42ft long from mh. Contractor confirm depth/location, follow detail p262. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104179-000 | |||||
Storm only, 2 of 2: contractor to make connection to public branch from mh abu844 in sw river dr. Main line is 24in rcp approx depth 19ft, branch approx 37ft long from mh. Contractor confirm depth/location, follow detail p262. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104181-000 | |||||
Utilities including 248 ft storm, 117 ft sanitary sewer and 1 ft water service-this permit for all utilities for 15-104147 uc/15-104177 uc/15-104179 uc/ 15-104181 uc Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104188-000 | |||||
Generator temporary power for trailer Date: January 16, 2015Permit type: Electrical inspections | Permit status: Approved | Completion date: February 6, 2015 | Permit id: 2015-106396-000 | |||||
Two 15-ton gas packs for corridors/doas, garage exhaust, vrf for apartments and common spaces, pool dehumidification unit, subduct fans on epwr, plans w/co Date: June 1, 2015Permit type: Intake | Permit status: Closed | Completion date: February 3, 2015 | Permit id: 2015-108160-000 | |||||
Sprinkler-install complete wet combo standpipe in new six story hotel w/ floor controls. Install complete dry system in parking garage. Date: June 2, 2015Permit type: Intake | Permit status: Approved | Completion date: May 1, 2015 | Permit id: 2015-162467-000 | |||||
149 unit building. Largest unit is 7 sqft - oar 918 reduced fees apply only to residential units. Permit type: Intake | Permit status: Closed | Completion date: May 19, 2015 | Permit id: 2015-173059-000 | |||||
Intake pw Date: January 22, 2015Permit status: Assigned | Completion date: December 1, 2014 | Permit id: 2014-156602-000 | |||||
Set fee Permit type: Intake -we | Permit status: Closed | Completion date: May 16, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Intake -we | Permit status: Closed | Completion date: May 19, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Issuance -we | Permit status: Closed | Completion date: January 22, 2015 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: July 16, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: July 17, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: October 3, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: October 13, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: September 17, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: June 5, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: November 25, 2014 | Permit id: 2014-158638-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: May 29, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Closed | Completion date: October 29, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Closed | Completion date: June 4, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: July 11, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: July 17, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: July 16, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: October 2, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: August 11, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: July 24, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: August 29, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: October 23, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: October 30, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: November 17, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Land use review | Permit status: Completed | Completion date: December 3, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Site development | Permit status: Response sent | Completion date: August 11, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Site development | Permit status: No concerns | Completion date: June 4, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Life safety | Permit status: Response sent | Completion date: July 22, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Fire bureau | Permit status: Response sent | Completion date: August 7, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Environmental services | Permit status: Response sent | Completion date: August 12, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Environmental services | Permit status: Response sent | Completion date: August 4, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Environmental services | Permit status: Response sent | Completion date: June 17, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Transportation | Permit status: Response sent | Completion date: August 8, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Transportation | Permit status: No concerns | Completion date: June 5, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Water bureau review | Permit status: Response sent | Completion date: July 30, 2014 | Permit id: 2014-162150-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Permit type: Parks bureau | Permit status: No concerns | Completion date: July 22, 2014 | Permit id: 2014-162150-000 | |||||
6-story hotel. 1st floor will be type ia construction and provide lobby, casual dining, pool, fitness, laundry, food prep, meeting rooms and valet parking. Floors 2-6 will be type iiib construction and provide 39-41 guest units per floor for 203 total guest units. Outdoor terrace space will be provided on floor 2. Date: May 28, 2015Permit type: Application | Permit status: Approved | Completion date: February 2, 2015 | Permit id: 2014-201514-000 | |||||
Dfs for post tension for fnd permit Date: May 8, 2015Permit type: Application | Permit status: Approved | Completion date: March 30, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for autotight holdown system Permit type: Application | Permit status: Approved | Completion date: June 16, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for autotight holdown system Permit type: Issuance/intake | Permit status: Intake | Completion date: June 17, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for autotight holdown system Permit type: Process management | Permit status: Closed | Completion date: July 2, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for autotight holdown system Permit type: Life safety | Permit status: Not reqd | Completion date: July 1, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for autotight holdown system Permit type: Structural | Permit status: Approved | Completion date: June 19, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for autotight holdown system Permit type: Issuance | Permit status: Approved | Completion date: July 2, 2015 | Permit id: 2014-201514-Dfs | |||||
Foundation and concrete work up to the top of level 2 concrete deck. This includes excavation, piles, grade beams, pile caps, columns, level 1 slabs and level 2 concrete deck. Concrete, paving, and stormwater work within sw moody, the private driveway east of the site. Date: January 6, 2015Permit type: Application | Permit status: Approved | Completion date: September 2, 2014 | Permit id: 2014-201514-Fnd | |||||
Rev 01 - re-designed foundation to support tower crane Date: February 10, 2015Permit type: Application | Permit status: Approved | Completion date: January 27, 2015 | Permit id: 2014-201514-Rev | |||||
Relocate the electrical transformer from below sidewalk along sw moody ave to inside the parking structure. Date: January 27, 2015Permit type: Application | Permit status: Approved | Completion date: January 21, 2015 | Permit id: 2014-201514-Rev | |||||
Revise erosion control - second proposed temporary construction access Date: May 8, 2015Permit type: Application | Permit status: Approved | Completion date: March 3, 2015 | Permit id: 2014-201514-Rev | |||||
Design changes to the sw corner of level 1 only, with modifications made to the layout of the bar, guest kitchen and some of the public seating areas. Date: July 6, 2015Permit type: Application | Permit status: Approved | Completion date: June 9, 2015 | Permit id: 2014-201514-Rev | |||||
Deq lucs for stormwater Permit type: Land use review | Permit status: Closed | Completion date: November 7, 2014 | Permit id: 2014-235461-000 | |||||
Deq lucs for stormwater Permit type: Land use review | Permit status: Letter sent | Completion date: December 1, 2014 | Permit id: 2014-235461-000 | |||||
Street tree pruning permit Date: July 30, 2015Permit type: D - permit request | Permit status: Permit issued | Completion date: July 30, 2015 | Permit id: 2015-208810-000 | |||||
Underground-trench for and install 6 fire line including fdc, ddcv and vault Date: December 30, 2015Permit type: Intake | Permit status: Approved | Completion date: September 15, 2015 | Permit id: 2015-236387-000 | |||||
Plumbing fixtures for ivr #3565805 Date: September 15, 2015Permit type: Intake | Permit status: Closed | Completion date: September 15, 2015 | Permit id: 2015-236751-000 | |||||
Alarm - installation of fire alarm system for new building Date: October 23, 2015Permit type: Intake | Permit status: Approved | Completion date: October 2, 2015 | Permit id: 2015-245920-000 | |||||
Install (1) illuminated flush mounted wall sign, 25 sq ft, west elevation. Date: November 2, 2015Permit type: Intake | Permit status: Closed | Completion date: November 2, 2015 | Permit id: 2015-259483-000 | |||||
Install (1) illuminated flush mounted wall sign, 25 sq ft, south elevation Date: November 2, 2015Permit type: Intake | Permit status: Closed | Completion date: November 2, 2015 | Permit id: 2015-259484-000 | |||||
Install (2) sign circuits Date: November 2, 2015Permit type: Intake | Permit status: Closed | Completion date: November 2, 2015 | Permit id: 2015-259486-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Land use review | Permit status: Completed | Completion date: January 12, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Land use review | Permit status: Completed | Completion date: February 23, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Land use review | Permit status: Completed | Completion date: March 3, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Site development | Permit status: No concerns | Completion date: March 8, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Life safety | Permit status: Response sent | Completion date: March 21, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Fire bureau | Permit status: Response sent | Completion date: March 21, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Environmental services | Permit status: Response sent | Completion date: March 22, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Environmental services | Permit status: Response sent | Completion date: March 9, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Water bureau review | Permit status: Response sent | Completion date: March 17, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Parks bureau | Permit status: Response sent | Completion date: March 28, 2016 | Permit id: 2016-102498-000 | |||||
Alarm - installation of das system Date: March 18, 2016Permit type: Intake | Permit status: Approved | Completion date: February 18, 2016 | Permit id: 2016-121878-000 | |||||
Storm only, 2 of 2: contractor to make connection to public branch from mh abu844 in sw river dr. Main line is 24in rcp approx depth 19ft, branch approx 37ft long from mh. Contractor confirm depth/location, follow detail p262. Date: February 19, 2016Permit type: Intake | Permit status: Closed | Completion date: February 19, 2016 | Permit id: 2016-123578-000 | |||||
Sanitary only, 2 of 2: contractor shall build new branch per std p-262 by installing inside drop per cop std detail p-253 in sw river dr. Mh approx depth 12. 3ft. Contractor confirm depth/location. Connection change ok & approved by joe blanco x3-2059 Date: February 19, 2016Permit type: Intake | Permit status: Closed | Completion date: February 19, 2016 | Permit id: 2016-123583-000 | |||||
Install 3 lineal ft storm sewer and 159 lineal ft water service on property Date: February 19, 2016Permit type: Intake | Permit status: Closed | Completion date: February 19, 2016 | Permit id: 2016-123606-000 | |||||
Low voltage sound system Date: March 15, 2016Permit type: Intake | Permit status: Closed | Completion date: March 15, 2016 | Permit id: 2016-135663-000 | |||||
Hazardous-provide and install a 90kw stand by diesel engine generator. The fuel tank is a 145 gallon sub-base tank with remote fuel station. Permit type: Intake | Permit status: Approved | Completion date: April 8, 2016 | Permit id: 2016-147507-000 | |||||
Hazardous-provide and install a 90kw stand by diesel engine generator. The fuel tank is a 145 gallon sub-base tank with remote fuel station. Permit type: Intake | Permit status: Closed | Completion date: April 8, 2016 | Permit id: 2016-147507-000 | |||||
Set fee Permit type: Intake -we | Permit status: Closed | Completion date: May 16, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Intake -we | Permit status: Closed | Completion date: May 19, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Issuance -we | Permit status: Closed | Completion date: January 22, 2015 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: July 16, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: July 17, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: October 3, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: October 13, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: September 17, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: June 5, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: November 25, 2014 | Permit id: 2014-158638-000 | |||||
It is the decision of the design commission to approve a type iii design review and concurrent greenway review for a new 6-story hyatt house hotel with ground floor retail, 203 hotel rooms, structured valet parking for 44 cars, and ecoroofs, designed as a courtyard style building finished in brick, slate tiles, and zinc panels with fiberglass upper story windows, aluminum storefront, curtainwall, steel planters, and a water feature and plant wall at the ground floor;approval of the following modification requests:1. Ground floor windows (33. 130. 230). To reduce the amount of ground floor windows on the east faade from 50% of the faade length and 25% of area of the faade to 35% length and 418 sf area instead of the required 441 sf area. 2. Loading standards (33. 266. 310) to locate the two required standard a loading spaces into the drive aisle area of the valet parking within the building; andapprovals per exhibits c. 1-c-54, signed, stamped, and dated october 24, 2014, subject to the fol Date: October 30, 2014Permit type: Land use review | Permit status: Completed | Completion date: May 29, 2014 | Permit id: 2014-162150-000 | |||||
Dfs for autotight holdown system Date: July 13, 2015Permit type: Application | Permit status: Approved | Completion date: June 16, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for roof trusses Date: September 22, 2015Permit type: Application | Permit status: Approved | Completion date: August 31, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Application | Permit status: Approved | Completion date: November 19, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Issuance/intake | Permit status: Intake | Completion date: November 19, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Process management | Permit status: Closed | Completion date: November 20, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Process management | Permit status: Closed | Completion date: March 1, 2016 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Planning and zoning | Permit status: Not reqd | Completion date: November 23, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Life safety | Permit status: Not reqd | Completion date: November 20, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for storefront and curtain wall Date: January 12, 2016Permit type: Application | Permit status: Approved | Completion date: December 18, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for fiberglass windows Date: February 26, 2016Permit type: Application | Permit status: Approved | Completion date: January 15, 2016 | Permit id: 2014-201514-Dfs | |||||
Dfs for gunite shell installed over structural enclosure Date: April 20, 2016Permit type: Application | Permit status: Approved | Completion date: March 30, 2016 | Permit id: 2014-201514-Dfs | |||||
There is an owner provided utility easement on the north side of the property which requires moving the fdc vault to the south. The new 6 fire line will connect to the existing 12 water main 3 south of original plan. The new 8 s. S. Line will tap directly to the s. S. Line instead of tapping into the manhole as originally planned. There was an existing s. S. In service at the original manhole tap location. Plan sheet c2 is the only sheet revised. Date: December 18, 2015Permit type: Application | Permit status: Approved | Completion date: October 14, 2015 | Permit id: 2014-201514-Rev | |||||
Rev 06 - update sheet s001 to remove i-joist from deferred submittal list Date: January 12, 2016Permit type: Application | Permit status: Approved | Completion date: December 18, 2015 | Permit id: 2014-201514-Rev | |||||
Value added revision to add 18 suv car stackers to the parking garage Date: April 20, 2016Permit type: Application | Permit status: Approved | Completion date: March 4, 2016 | Permit id: 2014-201514-Rev | |||||
Temporary power service - (6) 2 amps or less, (1) 401-600, (30) branch circuits, (1) limited energy for phone faxed Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: December 30, 2014 | Permit id: 2014-254993-000 | |||||
Sanitary only, 1 of 2: contractor to tap existing mh and build lateral for connection to 8in csp sani-only public sewer main line in sw moody, approx depth 15. 8ft. Contractor verify depth/location in the field, follow city details p262, p150. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104147-000 | |||||
Storm only 1 of 2: contractor to tap existing mh, build lateral to property. Mh located in sw moody, 12in csp public storm main line, approx depth 17ft, contractor confirm depth/location in the field, follow city details p262/p150. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104177-000 | |||||
149 unit building. Largest unit is 7 sqft - oar 918 reduced fees apply only to residential units. / refund request routed to bwelland 12/18/2015 / Date: August 11, 2015Permit type: Intake | Permit status: Closed | Completion date: May 19, 2015 | Permit id: 2015-173059-000 | |||||
Low volt wiring and t-stats. 6th floor Date: May 22, 2015Permit type: Electrical inspections | Permit status: Approved | Completion date: November 5, 2015 | Permit id: 2015-174696-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Land use review | Permit status: Completed | Completion date: January 12, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Land use review | Permit status: Completed | Completion date: February 23, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Land use review | Permit status: Completed | Completion date: March 3, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Site development | Permit status: No concerns | Completion date: March 8, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Life safety | Permit status: Response sent | Completion date: March 21, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Fire bureau | Permit status: Response sent | Completion date: March 21, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Environmental services | Permit status: Response sent | Completion date: March 22, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Environmental services | Permit status: Response sent | Completion date: March 9, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Water bureau review | Permit status: Response sent | Completion date: March 17, 2016 | Permit id: 2016-102498-000 | |||||
Requesting revisions to an approved type 3 design review regarding landscaping, mechanical, and passenger loading zone. Permit type: Parks bureau | Permit status: Response sent | Completion date: March 28, 2016 | Permit id: 2016-102498-000 | |||||
Storm only, 2 of 2: contractor to make connection to public branch from mh abu844 in sw river dr. Main line is 24in rcp approx depth 19ft, branch approx 37ft long from mh. Contractor confirm depth location, follow detail p262. Date: February 19, 2016Permit type: Intake | Permit status: Closed | Completion date: February 19, 2016 | Permit id: 2016-123578-000 | |||||
Sanitary only, 2 of 2: contractor shall build new branch per std p-262 by installing inside drop per cop std detail p-253 in sw river dr. Mh approx depth 12. 3ft. Contractor confirm depth location. Connection change ok & approved by joe blanco x3-2059 Date: February 19, 2016Permit type: Intake | Permit status: Closed | Completion date: February 19, 2016 | Permit id: 2016-123583-000 | |||||
Hazardous-provide and install a 90kw stand by diesel engine generator. The fuel tank is a 145 gallon sub-base tank with remote fuel station. Permit type: Intake | Permit status: Approved | Completion date: April 8, 2016 | Permit id: 2016-147507-000 | |||||
Hazardous-provide and install a 90kw stand by diesel engine generator. The fuel tank is a 145 gallon sub-base tank with remote fuel station. Permit type: Intake | Permit status: Closed | Completion date: April 8, 2016 | Permit id: 2016-147507-000 | |||||
Set fee Permit type: Intake -we | Permit status: Closed | Completion date: May 16, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Intake -we | Permit status: Closed | Completion date: May 19, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Issuance -we | Permit status: Closed | Completion date: January 22, 2015 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: July 16, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: July 17, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: October 3, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: October 13, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: September 17, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: June 5, 2014 | Permit id: 2014-158638-000 | |||||
Set fee Permit type: Plan review -we | Permit status: Closed | Completion date: November 25, 2014 | Permit id: 2014-158638-000 | |||||
Dfs for mechanical equipment frames Permit type: Application | Permit status: Approved | Completion date: November 19, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Issuance/intake | Permit status: Intake | Completion date: November 19, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Process management | Permit status: Closed | Completion date: November 20, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Process management | Permit status: Closed | Completion date: March 1, 2016 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Planning and zoning | Permit status: Not reqd | Completion date: November 23, 2015 | Permit id: 2014-201514-Dfs | |||||
Dfs for mechanical equipment frames Permit type: Life safety | Permit status: Not reqd | Completion date: November 20, 2015 | Permit id: 2014-201514-Dfs | |||||
Sanitary only, 1 of 2: contractor to tap existing mh and build lateral for connection to 8in csp sani-only public sewer main line in sw moody, approx depth 15. 8ft. Contractor verify depth location in the field, follow city details p262, p150. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104147-000 | |||||
Storm only 1 of 2: contractor to tap existing mh, build lateral to property. Mh located in sw moody, 12in csp public storm main line, approx depth 17ft, contractor confirm depth location in the field, follow city details p262 p150. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104177-000 | |||||
Sanitary only, 2 of 2: contractor to make connection to public branch from mh abu855 in sw river dr. Main line is 10in ncp approx depth 12. 3ft, branch approx 42ft long from mh. Contractor confirm depth location, follow detail p262. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104179-000 | |||||
Storm only, 2 of 2: contractor to make connection to public branch from mh abu844 in sw river dr. Main line is 24in rcp approx depth 19ft, branch approx 37ft long from mh. Contractor confirm depth location, follow detail p262. Date: January 13, 2015Permit type: Intake | Permit status: Closed | Completion date: January 13, 2015 | Permit id: 2015-104181-000 | |||||
Two 15-ton gas packs for corridors doas, garage exhaust, vrf for apartments and common spaces, pool dehumidification unit, subduct fans on epwr, plans w co Date: June 1, 2015Permit type: Intake | Permit status: Closed | Completion date: February 3, 2015 | Permit id: 2015-108160-000 | |||||
Sprinkler-install complete wet combo standpipe in new six story hotel w floor controls. Install complete dry system in parking garage. Date: June 2, 2015Permit type: Intake | Permit status: Approved | Completion date: May 1, 2015 | Permit id: 2015-162467-000 | |||||
149 unit building. Largest unit is 7 sqft - oar 918 reduced fees apply only to residential units. Refund request routed to bwelland 12 18 2015 Date: August 11, 2015Permit type: Intake | Permit status: Closed | Completion date: May 19, 2015 | Permit id: 2015-173059-000 |