New 1000gal michaels to replace steel tank. Unknown if a drainfield or seepage pit. Uncover d-box, if there, carefully. High groundwater in area. Antibouyancy on tank is required and a new drainfield may be necessary depending on findings. Pt from cop to final. / see 15-102341 for df details Date: December 19, 2014Permit type: Intake | Permit status: Approved | Completion date: December 19, 2014 | Permit id: 2014-251734-000 | |||||
Foot sanitary sewer Date: December 19, 2014Permit type: Intake | Permit status: Closed | Completion date: December 19, 2014 | Permit id: 2014-251738-000 | |||||
Repair Date: December 29, 2014Permit type: Application | Permit status: Approved | Completion date: December 29, 2014 | Permit id: 2014-254097-000 | |||||
1000gal tank from 14-251734 sp to new aquasafe 5 to 5 x lines of 30, mainfold in center. Gravelless half pipe with 4 cover, max depth. Gwi upslope from top line daylighting 5ft from property line. Keep 20ft from roadside ditch. Date: January 8, 2015Permit type: Intake | Permit status: Approved | Completion date: January 8, 2015 | Permit id: 2015-102341-000 | |||||
Two septic circuits (20amp and 15amp, 120v) Date: January 23, 2015Permit type: Electrical inspections | Permit status: Approved | Completion date: February 20, 2015 | Permit id: 2015-109322-000 |