SCORE 96 34 sq ft, re-roof for (e) sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material tar and gravel built up proposed roofing material torch down manufacturer johns maville brand and model 4.. 25 fr crg color (if cool roof required) built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: January 2, 2018 | Permit id: Pds2017-Resalt- | |||||
SCORE 95 Replacement entry & garare door () (same net area) for (e) sfd Date: October 31, 2017 Contractor: Sears Home Improvement Products IncPermit type: Addn | Permit status: Issued | Permit id: Pds2017-Resalt- |