ACTIVITY
PERMITS VALUATION
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
SCORE 83 Install 3. 2 kw solar pv on roof Client: Galblum Amy | Permit type: Solar panels | Current use: 1-2fam | Permit id: E124688 | Parcel: 1804995001 | |||||
SCORE 84 Installation of 14 canadian solar cs6p-230p solar modules. Modules will be mounted using stainless steel ecofasten mounting hardware. Each module is attached to two rails that are attached to the roof every 4? Depending on rafter spacing. Mounting feet will be attached rafters using 5/16" lag bolts that will penetrate 3" into the existing rafters. The mounting system will be designed to withstand code mandated mph winds and snow loads of lbs psf. The existing roof conditions consist of a 10/12 pitch with true 2" x 6 1/4" rafters that are 18" on center with an 11 span. There is also a structural knee wall as well as collar ties every other rafter. Client: Galblum Amy | Permit type: Solar panels | Permit status: Expired | Current use: 1-2fam | Permit id: Sf113300 | Parcel: 1804995001 | |||||
SCORE 59 Off-street parking for two residential vehicles Client: Galblum Amy | Permit type: Driveway installation | Current use: 1-2fam | Permit id: U4938280 | Parcel: 1804995001 | |||||
SCORE 83 Install 3. 2 kw solar pv on roof Client: Galblum Amy | Permit type: Electrical permit | Expiration date: September 13, 2012 | Current use: 1-2fam | Permit id: E124688 | Parcel: 1804995001 | |||||
SCORE 59 Off-street parking for two residential vehicles Client: Galblum Amy | Permit type: Use of premises | Expiration date: May 3, 2011 | Current use: 1-2fam | Permit id: U4938280 | Parcel: 1804995001 | |||||
SCORE 84 Installation of 14 canadian solar cs6p-230p solar modules. Modules will be mounted using stainless steel ecofasten mounting hardware. Each module is attached to two rails that are attached to the roof every 4 depending on rafter spacing. Mounting feet will be attached rafters using 5/16" lag bolts that will penetrate 3" into the existing rafters. The mounting system will be designed to withstand code mandated mph winds and snow loads of lbs psf. The existing roof conditions consist of a 10/12 pitch with true 2" x 6 1/4" rafters that are 18" on center with an 11 span. There is also a structural knee wall as well as collar ties every other rafter. Client: Galblum Amy | Permit type: Short form bldg permit | Expiration date: July 13, 2012 | Current use: 1-2fam | Permit id: Sf113300 | Parcel: 1804995001 |