ACTIVITY
PERMITS VALUATION
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
195 unit building. Largest unit is 1328 sqft - oar 918 reduced fees apply only to residential units. Date: January 7, 2015Permit type: Intake | Permit status: Closed | Completion date: December 8, 2014 | Permit id: 2014-246879-000 | |||||
Alarm - fire alarm system for new apartment building Date: February 10, 2015Permit type: Intake | Permit status: Approved | Completion date: January 21, 2015 | Permit id: 2015-107531-000 | |||||
Alarm-distributed antenna system for new apartment building Date: March 25, 2015Permit type: Intake | Permit status: Approved | Completion date: January 20, 2015 | Permit id: 2015-107534-000 | |||||
Sprinkler-fire pump, fire sprinkler system, standpipes Date: April 22, 2015Permit type: Intake | Permit status: Approved | Completion date: March 25, 2015 | Permit id: 2015-140004-000 | |||||
Plumbing systems and fixtures new commercial-excluding underslab see permit 15-107317pt Date: April 14, 2015Permit type: Intake | Permit status: Closed | Completion date: April 8, 2015 | Permit id: 2015-146686-000 | |||||
15 story mixed use, 196 apartments, 8,9 sf retail, 2 levels subgrade parking Date: March 20, 2015Permit type: Application | Permit status: Approved | Completion date: June 30, 2014 | Permit id: 2014-167510-000 | |||||
Dfs 1 : for post tension slabs this dfs for the str permit, main permit is still under review Date: February 2, 2015Permit type: Application | Permit status: Approved | Completion date: December 22, 2014 | Permit id: 2014-167510-Dfs | |||||
Dfs 2 : for stairs Date: May 12, 2015Permit type: Application | Permit status: Approved | Completion date: March 13, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 3 : exterior stone cladding Permit type: Application | Permit status: Approved | Completion date: May 4, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 3 : exterior stone cladding Permit type: Issuance/intake | Permit status: Intake | Completion date: May 4, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 3 : exterior stone cladding Permit type: Process management | Permit status: Closed | Completion date: May 4, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 3 : exterior stone cladding Permit type: Planning and zoning | Permit status: Approved | Completion date: June 18, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 3 : exterior stone cladding Permit type: Life safety | Permit status: Approved | Completion date: May 6, 2015 | Permit id: 2014-167510-Dfs | |||||
Partial permit : excavation and shoring 15 story mixed use, 196 apartments, 8,9 sf retail, 2 levels subgrade parking Date: September 25, 2014Permit type: Application | Permit status: Approved | Completion date: June 30, 2014 | Permit id: 2014-167510-Exc | |||||
Revision 1 : embeds 15 story mixed use, 196 apartments, 8,9 sf retail, 2 levels subgrade parking Date: February 12, 2015Permit type: Application | Permit status: Approved | Completion date: February 6, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 2 : plumbing revisions 15 story mixed use, 196 apartments, 8,9 sf retail, 2 levels subgrade parking Date: May 1, 2015Permit type: Application | Permit status: Approved | Completion date: April 17, 2015 | Permit id: 2014-167510-Rev | |||||
Partial for foundation to l3 and underslab plumbing 15 story mixed use, 196 apartments, 8,9 sf retail, 2 levels subgrade parking Date: December 19, 2014Permit type: Application | Permit status: Approved | Completion date: December 16, 2014 | Permit id: 2014-167510-Str | |||||
Temp power for site construction Date: October 1, 2014Permit type: Intake | Permit status: Closed | Completion date: September 19, 2014 | Permit id: 2014-215502-000 | |||||
Stm conn: 291 lf of 12 ncp main in sw jefferson st. Approx depth 15. Contractor to install 8 x 12 tee into 12 main and prepare 8 branch to property per std p-262. Contractor to verify all depths and connections in field. X37869 Date: October 20, 2014Permit type: Intake | Permit status: Closed | Completion date: October 20, 2014 | Permit id: 2014-227840-000 | |||||
San conn: 2 lf of 9 vsp main in sw jefferson st. Approx depth 11. Contractor to install 8 x 9 tee into 9 main and prepare 8 branch to property per std p-262. Contractor to verify all depths and connections in field. X37869 Date: January 14, 2016Permit type: Intake | Permit status: Closed | Completion date: January 14, 2016 | Permit id: 2016-105845-000 | |||||
Dfs 3 : exterior stone cladding Date: August 7, 2015Permit type: Application | Permit status: Approved | Completion date: May 4, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 4 : exterior metal panels Date: September 17, 2015Permit type: Application | Permit status: Approved | Completion date: August 7, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 5 : exterior vinyl windows and doors Date: September 28, 2015Permit type: Application | Permit status: Approved | Completion date: August 21, 2015 | Permit id: 2014-167510-Dfs | |||||
Dfs 6 : storefront windows Date: April 12, 2016Permit type: Application | Permit status: Approved | Completion date: February 17, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 7 : aluminum balconies and steel railings Date: April 12, 2016Permit type: Application | Permit status: Approved | Completion date: February 17, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 8 : car stackers Date: March 21, 2016Permit type: Application | Permit status: Approved | Completion date: February 24, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Application | Permit status: Approved | Completion date: March 24, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Issuance/intake | Permit status: Intake | Completion date: March 24, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Process management | Permit status: Closed | Completion date: March 24, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Process management | Permit status: Closed | Completion date: April 21, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Life safety | Permit status: Not reqd | Completion date: April 7, 2016 | Permit id: 2014-167510-Dfs | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Application | Permit status: Approved | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Application | Permit status: Approved w/ cond | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Issuance/intake | Permit status: Intake | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Process management | Permit status: Closed | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Process management | Permit status: Closed | Completion date: November 25, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Life safety | Permit status: Not reqd | Completion date: November 23, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Structural | Permit status: Approved | Completion date: November 19, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6/s8. 04, 7/s8. 04, 8/s8. 04, 9/s8. 04, 13/s3. 04, 15/s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19/s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18/s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8/s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17/s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16/s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14/s6. 05, added reference on 14/s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13/s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12/s6. 05 - fix for misplaced exter Permit type: Issuance | Permit status: Approved | Completion date: November 25, 2015 | Permit id: 2014-167510-Rev | |||||
195 unit building. Largest unit is 1328 sqft - oar 918 reduced fees apply only to residential units. / refund request routed to bwelland 12/18/2015 / Date: January 7, 2015Permit type: Intake | Permit status: Closed | Completion date: December 8, 2014 | Permit id: 2014-246879-000 | |||||
Dfs 9 : fall prevention devices Permit type: Application | Permit status: Approved | Completion date: March 24, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Issuance/intake | Permit status: Intake | Completion date: March 24, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Process management | Permit status: Closed | Completion date: March 24, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Process management | Permit status: Closed | Completion date: April 21, 2016 | Permit id: 2014-167510-Dfs | |||||
Dfs 9 : fall prevention devices Permit type: Life safety | Permit status: Not reqd | Completion date: April 7, 2016 | Permit id: 2014-167510-Dfs | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Application | Permit status: Approved | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Application | Permit status: Approved w/ cond | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Issuance/intake | Permit status: Intake | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Process management | Permit status: Closed | Completion date: November 16, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Process management | Permit status: Closed | Completion date: November 25, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Life safety | Permit status: Not reqd | Completion date: November 23, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Structural | Permit status: Approved | Completion date: November 19, 2015 | Permit id: 2014-167510-Rev | |||||
Revision 3 - rfi s113 revised details 6 s8. 04, 7 s8. 04, 8 s8. 04, 9 s8. 04, 13 s3. 04, 15 s3. 04 - removeredundant reinforcement; rfi s113. 001. Rfi s117 new detail 19 s6. 05, added reference on s2. 03b fix for incorrect shim size placed during construction; rfi s118 new detail 18 s6. 05, added reference on s2. 03b - fix for shims placed in incorrect location during construction; rfi s124 revised detail 8 s8. 06 fix for embed placed in incorrect location during construction; rfi s125 new detail 17 s6. 05, added reference on s2. 04 - fix for embed angle omitted during construction; rfi s131new detail 16 s6. 05, added (4) references on s2. 04 - fix for steel fabrication error; rfis134 new detail 14 s6. 05, added reference on 14 s8. - alternative connection for exterior panel. Adjacent to windows, horizontal member made drive pin installation difficult: rfi s134. 00, rfi s141 new detail 13 s6. 05 - fix for misplaced interior panel during construction. Rfi s147 new detail 12 s6. 05 - fix for misplaced exter Permit type: Issuance | Permit status: Approved | Completion date: November 25, 2015 | Permit id: 2014-167510-Rev | |||||
195 unit building. Largest unit is 1328 sqft - oar 918 reduced fees apply only to residential units. Refund request routed to bwelland 12 18 2015 Date: January 7, 2015Permit type: Intake | Permit status: Closed | Completion date: December 8, 2014 | Permit id: 2014-246879-000 |