ACTIVITY
PERMITS VALUATION
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
-repair principal entry door and sill as needed to match existing. Date: April 24, 2014Permit type: Vcc general work | Permit status: Permit issued | Expiration date: October 24, 2014 | Current use: Half of a party wall double | Permit id: 14-12791-Vcgen | |||||
SCORE 56 Remove 4x4 section of eternit roof slates to repair rotted beam underneath; replace decking, felt and roof slates. Repair minor rot damage in front gallery deck and paint to match existing: deck gray. Repair and rehang front door. Permit type: Vcc general work | Permit status: Permit issued | Expiration date: November 2, 2013 | Current use: Single family | Permit id: 13-13776-Vcgen | |||||
Historical import type: enforcement vcc permit paintuser: rpelltracking: 86168712418status: permit issuedstatus date: 3/19/2012 12:00: amowner: cadow ralph lowner address: 1127 royal st, new orleans, la 70116owner edited by: 3/19/2012 by rpell Date: March 19, 2012Permit type: Vcc paint | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0263 | |||||
Historical import type: enforcement vcc permit generaluser: cabergtracking: 86118018820status: permit issuedstatus date: 4/2/2012 12:00: amowner: cadow ralph lowner address: 1127 royal st, new orleans, la 70116owner edited by: 4/2/2012 by caberg Date: April 2, 2012Permit type: Vcc general work | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0320 | |||||
Emergency use of tarp for weather-proofingremove existing damaged roofing material repair and/or replace underlayment as necessaryinstall new or reinstall salvaged natural slate (grey/green), using copper nailsinstall/repair copper flashing metal cap-flashing on the parapets is not allowednote: trash chutes are required for removal of debris from all roofs. All work must conform to standard vcc policies & guidelines. Permit does not allow for cap flashing on parapet or surrounding walls. Torch-applied roofing is not permitted in the vieux carr. Date: December 22, 2014Permit type: Vcc general work | Permit status: Permit issued | Expiration date: June 22, 2015 | Current use: Business use | Permit id: 14-39374-Vcgen | |||||
-repair/patch 3 x 3 section of sidewalk to match existing adjacent sidewalk with like materials (concrete) Date: July 8, 2013Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 18, 2014 | Current use: Half of a party wall double | Permit id: 13-29757-Vcgen | |||||
Historical import type: enforcement vcc permit generaluser: cabergtracking: 86118018820status: permit issuedstatus date: 4 2 2012 12:00: amowner: cadow ralph lowner address: 1127 royal st, new orleans, la 70116owner edited by: 4 2 2012 by caberg Date: April 2, 2012Permit type: Vcc general work | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0320 | |||||
Emergency use of tarp for weather-proofingremove existing damaged roofing material repair and or replace underlayment as necessaryinstall new or reinstall salvaged natural slate (grey green), using copper nailsinstall repair copper flashing metal cap-flashing on the parapets is not allowednote: trash chutes are required for removal of debris from all roofs. All work must conform to standard vcc policies & guidelines. Permit does not allow for cap flashing on parapet or surrounding walls. Torch-applied roofing is not permitted in the vieux carr. Date: December 22, 2014Permit type: Vcc general work | Permit status: Permit issued | Expiration date: June 22, 2015 | Current use: Business use | Permit id: 14-39374-Vcgen | |||||
-repair patch 3 x 3 section of sidewalk to match existing adjacent sidewalk with like materials (concrete) Date: July 8, 2013Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 18, 2014 | Current use: Half of a party wall double | Permit id: 13-29757-Vcgen | |||||
Historical import type: enforcement vcc permit paintuser: rpelltracking: 86168712418status: permit issuedstatus date: 3 19 2012 12:00: amowner: cadow ralph lowner address: 1127 royal st, new orleans, la 70116owner edited by: 3 19 2012 by rpell Date: March 19, 2012Permit type: Vcc paint | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0263 | |||||
SCORE 71 Roof repair to existing single. Replace slates on hip of roof and replace rotten sheathing undeneath, install moisture barrier and copper flashing per vcc. No structural changes. Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: February 25, 2018 | Current use: Single family | Permit id: 17-28920-Rnvn | |||||
Remove deteriorated floor boards and fascia boards from royal balcony. Install new 5 4x4 s2s t&g floorboards and 7 8" fascia with " bead, all as per vcc standard detail sheet no. 12 (attached)paint decking and underside to match existing:decking... Deck gray, ben. Moore, semiglossunderside... Marrero white, ben. Moore, semiglossall repair replacement work shall match existing in color, size, material, detail, profile and exposureclean and paint ironwork to match existing:ironwork... Black Date: March 20, 2017Permit type: Vcc general work | Permit status: Permit finaled | Completion date: October 27, 2017 | Expiration date: September 20, 2017 | Current use: Single family | Permit id: 17-09314-Vcgen | |||||
Remove existing fire free plus roofing material repair and or replace underlayment as necessary install new 18 x 12 natural slate (grey green), using copper nails install repair half round copper gutters and flashing install reinstall ceramic or concrete v-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets is not allowednote: trash chutes are required for removal of debris from all roofs all work must conform to standard vcc policies & guidelines permit does not allow for cap flashing on parapet or surrounding wallstorch-applied roofing is not permitted in the vieux carr. All repair replacement work shall match existing in color, size, material, detail, profile and exposure Date: August 23, 2017Permit type: Vcc general work | Permit status: Permit issued | Expiration date: February 24, 2018 | Current use: Single family | Permit id: 17-28920-Vcgen | |||||
Dumpster in the parking lane on royal. Date: September 7, 2017Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: March 7, 2018 | Current use: Half of a party wall double | Permit id: 17-30641-Rczd | |||||
SCORE 62 To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: wooden elements including doors, windows, frames, shop windows, fascia/soffit/outriggers of gallery... Marrero white, ben. Moore, semiglossthis permit prohibits the application of the following exterior coating materials and paints: sealers, ceramic coatings/paints, elastomeric coatings/paints, waterproofing/water repellent coatings. Permit type: Vcc paint | Permit status: Permit issued | Expiration date: April 7, 2015 | Current use: Half of a party wall double | Permit id: 14-30350-Vcpnt |