QUALITY
ACTIVITY
AVERAGE PROJECT COST
PERMITS VALUATION
PROJECTS PER TOWN:
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
SCORE 80 Client: Lashlee Basement Repair | Permit type: Res: remodel | Permit status: Closed | Current use: Residential | Permit id: 07-00556 | Parcel: 23300 | |||||
SCORE 80 Client: Anderson Repairs | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 05-03676 | Parcel: 33933 | |||||
SCORE 80 65 Swannanoa Ave, Asheville, Nc 28806 Comment date: wed jul 07 00:00: edt 2004 - residential repairs to foundation for kixt residence;scc; comment date: fri jul 09 00:00: edt 2004 - amendment-concrete wall supporting crawl space. Lcs; com Client: Kixt Repairs | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 04-03192 | Parcel: 13433 | |||||
SCORE 80 1 Park Ridge Ct, Asheville, Nc 288032061 Ellis basement stabilization;scc; foundation stabilization using engineered design to install 6x6 p. T. Posts at 32" on center, supported by bracket on basement slab and 4x4 blocks and bolt-thru-joist connection at the top. Engineered drawing shall be on the jobsite for the inspection. Note!!! - the inspector will turn down an inspection if the permit, approved plans, and plan review comments are not on the jobsite. For building inspections call jim reato at redacted phone number. No electrical, plumbing, or heating/mechanical work included in the permit at this time. Client: Ellis Basement | Permit type: Res: remodel | Permit status: Closed | Current use: Residential | Permit id: 05-01224 | Parcel: 34232 | |||||
SCORE 80 111 Flint St, Asheville, Nc 28801 December 1, 2006 10:20:33 am dshook anderson - repair foundation and stucco; importanat details from hrc what the inspector needs to know is that we have approved the foundation repairs suggested by the engineer with the exception of the application of surwall on top of the brick. Nothing at all should be applied to the brick after it has been repointed. The applicant is aware so it shouldnt be a problem, but i just wanted to have it in writing for the inspector. Thanks for your help, jennifer blevins/pmd; june 25, 2013 12:47:17 pm scarver. Voided due to time lapse and inactive contractor;scc; building safety review comments the approved plans with the attached review comments are required to be at the job site for use by the field inspector(s) at all times. The building permit is required to be posted at the jobsite at all times. Failure to post approved permits & plans at site is a fine, fine must be paid before next inspection is requested. To request residentia Client: Anderson - Repairs | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 06-05846 | Parcel: 7737 | |||||
SCORE 80 616 Marietta St, Asheville, Nc 28803 Mills foundation repairs based on engineers report. Pmd; structural foundation and floor framing repairs per engineers report (brooks & medlock). Building comments: the engineers report and drawings, and the building permit are required to be kept on the jobsite for viewing by the city inspectors. The building permit is required to be posted on the job site at all times during the project. The permit shall be in a weathertight location or a container that is accessible to the city inspectors during their inspections. Note!!! - the inspector will turn down an inspection if the permit, approved plans, and plan review comments are not on the jobsite. For building inspections call jim reato at redacted phone number. No plumbing, electrical, or mechanical/hvac work included in the permit. Footing inspection is required. The new footings are required to be inspected after the footing trenches have been excavated and the re Client: Mills Repairs | Permit type: Res: remodel | Permit status: Closed | Current use: Residential | Permit id: 05-03388 | Parcel: 32329 |