ACTIVITY
PERMITS VALUATION
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Alteration permit Date: November 17, 2016Client: Pernitsky Joseph | Permit status: Active | Permit id: 735970 | |||||
SCORE 99 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: August 30, 2017 Contractor: D R Builders 35 LlcClient: Pernitsky Joseph | Permit type: Mechanical permit | Permit status: Active | Completion date: September 20, 2017 | Permit id: 812508 | |||||
SCORE 100 For the installation of a 13r fire supression system for a multi-family dwelling serviced by a 2 inch fire service line with a back flow preventer assembly and residential fire pump. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Fire suppression system to be installed in accordance with nfpa 13r. Date: October 19, 2017 Contractor: B. M. Consulting Services IncClient: Pernitsky Joseph | Permit type: Suppression permit | Permit status: Active | Completion date: November 9, 2017 | Permit id: 812549 | |||||
SCORE 89 Total rewire of unit #1 and #2 with recepts,switches,lights,fixtures,smokes and co detectors on an existing 200amp service as per 2008 nec (cc district) no fire alarm Date: July 11, 2017 Contractor: D And R Company Electric LlcClient: Pernitsky Joseph | Permit type: Electrical permit | Permit status: Active | Completion date: August 24, 2017 | Permit id: 795649 | |||||
SCORE 99 For interior level 3 alterations and new certificate of occupancy for existing structure as per plans. Separate permits required for all mechanical, electrical and plumbing work. Date: June 28, 2017 Contractor: D R Builders 35 LlcClient: Pernitsky Joseph | Permit type: Alteration permit | Permit status: Active | Completion date: August 30, 2017 | Permit id: 782000 | |||||
SCORE 56 Ez permit stadard alterations- for alterations to an existing one family dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans.-(dry wall paint and spackle. Interior walls to existing open space no structual changes first floor) Date: November 17, 2016 Contractor: George E Atkins JrClient: Pernitsky Joseph | Permit type: Alteration permit | Permit status: Expired | Completion date: May 31, 2017 | Permit id: 735970 | |||||
For three (3) family dwelling (multi-family dwelling) in an existing structure. Date: April 24, 2017Client: Pernitsky Joseph | Permit type: Use permit | Permit status: Completed | Completion date: May 5, 2017 | Permit id: 759502 | |||||
SCORE 89 New 400amp services per nec 2008 and new fire alarm system per nfpa 72 only. Branch circuit wiring to be performed by others.(triplex) (cc district) Date: December 4, 2017 Contractor: D And R Company Electric LlcClient: Pernitsky Joseph | Permit type: Electrical permit | Permit status: Active | Completion date: December 4, 2017 | Permit id: 817311 |