Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Alteration permit Date: July 15, 2011 Permit status: Completed | Permit id: 343984 | |||||
Plumbing permit Date: July 15, 2011 Permit status: Completed | Permit id: 352537 | |||||
Alteration permit Date: April 24, 2012 Permit status: Expired | Permit id: 395160 | |||||
Electrical permit Date: July 13, 2011 Permit status: Expired | Permit id: 347906 | |||||
Alteration permit Date: April 24, 2012 Permit status: Expired | Permit id: 395160 | |||||
Electrical permit Date: July 13, 2011 Permit status: Expired | Permit id: 347906 | |||||
Alteration permit Date: July 15, 2011 Permit status: Completed | Permit id: 343984 | |||||
Plumbing permit Date: July 15, 2011 Permit status: Completed | Permit id: 352537 | |||||
SCORE 100 Minor remodel of the deli and speciality foods which will include relocating the existing hub drains for a new food display case layout and the installation of a hand sink Date: July 15, 2011 Contractor: Lgb Mechanical Inc Permit type: Plumbing permit | Permit status: Completed | Completion date: February 8, 2012 | Permit id: 352537 | |||||
SCORE 100 Full depth slab repair, new curb along ramp, concrete column extension, new precompressed foam seal, and repairs to one (1) expansion joint for parking garage. Date: April 24, 2012 Contractor: Pullman Sst Inc Permit type: Alteration permit | Permit status: Expired | Completion date: January 28, 2013 | Permit id: 395160 | |||||
SCORE 65 Interior level 2 alterations including remove and replace grocery display fixtures and new equipments as per plans. Separate permits required for all mechanical, electrical and plumbing work. Date: April 11, 2017 Contractor: Obarr Construction Llc Permit type: Alteration permit | Permit status: Completed | Completion date: September 25, 2017 | Permit id: 769562 | |||||
SCORE 86 Alterations: interior plumbing; grocery store - the installation will comply with the philadelphia plumbing code 2004. Date: July 5, 2017 Contractor: Churchville Mechanical Inc Permit type: Plumbing permit | Permit status: Completed | Completion date: September 25, 2017 | Permit id: 770724 | |||||
SCORE 82 Removal of existing hood and associated ductwork and installation of new ul listed captive-aire hood and associated ductwork within an existing grocery store as per approved plans. Date: April 12, 2017 Contractor: Precision Air Designs Inc Permit type: Mechanical permit | Permit status: Completed | Completion date: June 16, 2017 | Permit id: 771180 | |||||
SCORE 99 Refrigeration piping for store fixtures as per plan Date: May 11, 2017 Contractor: Capitol Refrigeration Inc Permit type: Alteration permit | Permit status: Completed | Completion date: September 25, 2017 | Permit id: 776673 | |||||
SCORE 86 Install one ansul fire suppression system ez standard kitchen fire suppression- for the installation of new wet chemical kitchen hood fire suppression system as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: May 2, 2017 Contractor: J And S Fire Protection Inc Permit type: Suppression permit | Permit status: Completed | Completion date: June 16, 2017 | Permit id: 780024 | |||||
SCORE 95 Replace 245 existing light fixtures with new led fixtures install 1 new seafood cooler, 3 phase 206v condenser 30a and lighting 2 install new under floor race way pvc conduit for relocated cooler cases 13 rework existing feeds for 11 new cases coolers to replace 11 existing as per nec 2008 south district Date: June 6, 2017 Contractor: Tangent Cable Systems Inc Permit type: Electrical permit | Permit status: Active | Completion date: June 6, 2017 | Permit id: 780747 | |||||
SCORE 100 Relocate (28) existing sprinkler heads. (commercial) Date: June 15, 2017 Contractor: Simplexgrinnell Permit type: Suppression permit | Permit status: Completed | Completion date: September 25, 2017 | Permit id: 792373 | |||||
SCORE 65 Interior alterations include remove and replace grocery display fixtures. For new equipment. Date: July 15, 2011 Contractor: Obarr Construction Llc Permit type: Alteration permit | Permit status: Completed | Completion date: February 8, 2012 | Permit id: 343984 | |||||
SCORE 86 Disconnect and relocate existing track lighting, run conduit and cable for 121 new refrigeration cases, and run low voltage control cables for the 12 cases as per 2008 nec (south dist) Date: July 13, 2011 Contractor: Foley, Paul Permit type: Electrical permit | Permit status: Expired | Completion date: August 10, 2011 | Permit id: 347906 |