Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 95 Installation & termination of 3 - #6 thwn copper conductors in new underground board conduits (by others) to obtain 1 volts from entergy vault to new wireless antenna poles, along with the grounding of poles. Permit type: Electrical service / circuit / feeder | Permit status: Permit issued | Expiration date: April 22, 2015 | Current use: Business use | Permit id: 14-32280-Serv | |||||
Repoint exterior brick as necessary on both main and service buildings. Replace brick as necessary with exactly matching brick. All mortar to be mixed following the vcc recipe below:mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. Note: ratio of portland cement not to exceed 1:12. To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: wooden elements including doors, windows, frames, shop windows, fascia/soffit/outriggers of gallery... Linen white pm-28, semigloss shutterspeppercorn sw 7674,semigloss ironwork ... Black balcony deckinggull wing graypaint for wooden elements and balcony decking to be benjamin moore brand, paint for shutters to be sher Date: December 9, 2015 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: June 9, 2016 | Current use: Half of a party wall double | Permit id: 15-36760-Vcgen | |||||
Repoint exterior brick as necessary on both main and service buildings. Replace brick as necessary with exactly matching brick. All mortar to be mixed following the vcc recipe below:mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. Note: ratio of portland cement not to exceed 1:12. To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: wooden elements including doors, windows, frames, shop windows, fascia soffit outriggers of gallery... Linen white pm-28, semigloss shutterspeppercorn sw 7674,semigloss ironwork ... Black balcony deckinggull wing graypaint for wooden elements and balcony decking to be benjamin moore brand, paint for shutters to be sher Date: December 9, 2015 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: June 9, 2016 | Current use: Half of a party wall double | Permit id: 15-36760-Vcgen |