Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Cogdill, greg Date: November 8, 2011 Permit status: Closed | Permit id: 11-05880 | |||||
SCORE 100 Cogdill, greg Client: Cogdill Mobile Home | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05880 | Parcel: 22187 | |||||
Cogdill, greg Value: $10,550 Client: Cogdill Mobile Home | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05880 | Parcel: 22187 | |||||
SCORE 98 Cogdill, greg Client: Cogdill Mobile Home | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05880 | Parcel: 22187 | |||||
October 12, 2011 11:38:48 am heatherr. Residential mobile home placement in park for greg cogdill to move in mobile home with (2) 4x8 decks and no heat pump; har location: north on leicester hwy t/l @ cvs, t/l at ol county home rd then t/l onto glimmer; november 8, 2011 4:40:03 pm kneel. Used mh to lot; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final Permit type: Permits - historical | Permit status: Closed | Permit id: 11-05880 | Parcel: 22187 | |||||
Cogdill, greg Date: November 8, 2011 Value: $10,550 Client: Cogdill Mobile Home | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05880 | Parcel: 22187 | |||||
October 12, 2011 11:38:48 am heatherr. Residential mobile home placement in park for greg cogdill to move in mobile home with (2) 4x8 decks and no heat pump; har location: north on leicester hwy t l @ cvs, t l at ol county home rd then t l onto glimmer; november 8, 2011 4:40:03 pm kneel. Used mh to lot; manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square feet requires separate deck permit. Building "final Date: November 8, 2011 Permit type: Permits - historical | Permit status: Closed | Permit id: 11-05880 | Parcel: 22187 |