-repoint mortar on uptown side of building with approved vcc mortar formula (below) to match existing as needed. Date: August 16, 2012 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: February 16, 2013 | Current use: Business use | Permit id: 12-22163-Vcgen | |||||
Replace rotten balcony decking to and paint to match existing. Remove deteriorated floor boards, stringers, and fascia boards as needed. Install new 3"x4" beaded stringers, 5/4x4 s2s t&g floorboards, and 7/8" fascia with " bead, all as per vcc standard detail sheet no. 12 (attached), as needed to match existing. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure Date: October 21, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: April 23, 2014 | Current use: Business use | Permit id: 13-42008-Vcgen | |||||
SCORE 95 Installation & termination of 3 - #6 thwn copper conductors in new underground board conduits (by others) to obtain 1 volts from entergy vault to new wireless antenna poles, along with the grounding of poles. Permit type: Electrical service / circuit / feeder | Permit status: Certificate of completion | Completion date: July 21, 2015 | Expiration date: April 22, 2015 | Current use: Business use | Permit id: 14-32287-Serv | |||||
SCORE 98 Remodel kitchen wire appliances , outlets & lights as per plan 15-24033-rnvn Date: September 3, 2015 Contractor: Dan Casadaban Permit type: Electrical repair / replacement / addition | Permit status: Permit issued | Expiration date: March 3, 2016 | Current use: Business use | Permit id: 15-26702-Erpr | |||||
Historical import type: enforcement vcc permit generaluser: rpelltracking: 86174679066status: permit issuedstatus date: 1/18/2012 12:00: amowner: davis mark c davis elizowner address: p o box 821, metairie, la 70004owner edited by: 1/18/2012 by rpellrepair existing single lite wood window to match existing shown in the attached photograph stamped approved on 1. 18. 12 Date: January 18, 2012 Permit type: Vcc general work | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0024 | |||||
Replace rotten balcony decking to and paint to match existing. Remove deteriorated floor boards, stringers, and fascia boards as needed. Install new 3"x4" beaded stringers, 5 4x4 s2s t&g floorboards, and 7 8" fascia with " bead, all as per vcc standard detail sheet no. 12 (attached), as needed to match existing. All repair replacement work shall match existing in color, size, material, detail, profile and exposure Date: October 21, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: April 23, 2014 | Current use: Business use | Permit id: 13-42008-Vcgen | |||||
Historical import type: enforcement vcc permit generaluser: rpelltracking: 86174679066status: permit issuedstatus date: 1 18 2012 12:00: amowner: davis mark c davis elizowner address: p o box 821, metairie, la 70004owner edited by: 1 18 2012 by rpellrepair existing single lite wood window to match existing shown in the attached photograph stamped approved on 1. 18. 12 Date: January 18, 2012 Permit type: Vcc general work | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0024 | |||||
SCORE 86 To remove the existing firefree roofing shingles. To install new natural vermont slate. To fabricate and install all necessary copper drip edge and copper step flashing. To fabricate and install copper step flashing and pin to masonry wall. Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Multi-family | Permit id: 17-37750-Rnvn | |||||
Remove existing fire free plus roofing material repair and or replace underlayment as necessaryinstall new natural slate (grey green), using copper nailsinstall repair half round copper gutters and flashinginstall reinstall ceramic or concrete v-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets is not allowednote: trash chutes are required for removal of debris from all roofs all work must conform to standard vcc policies & guidelines permit does not allow for cap flashing on parapet or surrounding wallstorch-applied roofing is not permitted in the vieux carr. All repair replacement work shall match existing in color, size, material, detail, profile and exposure. Date: November 8, 2017 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 9, 2018 | Current use: Multi-family | Permit id: 17-37750-Vcgen |