Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit Date: August 12, 2016 Client: Campanile Marie T | Permit status: Completed | Permit id: 705632 | |||||
New construction permit Date: August 8, 2016 Client: Campanile Marie T | Permit status: Active | Permit id: 683198 | |||||
Plumbing permit Date: May 27, 2016 Client: Campanile Marie T | Permit status: Active | Permit id: 695492 | |||||
Demolition permit Date: August 12, 2016 Client: Campanile Marie T | Permit status: Completed | Permit id: 705633 | |||||
Plumbing permit Date: May 27, 2016 Client: Campanile Marie T | Permit status: Completed | Permit id: 695492 | |||||
New construction permit Date: August 8, 2016 Client: Campanile Marie T | Permit status: Active | Permit id: 683198 | |||||
Demolition permit Date: August 12, 2016 Client: Campanile Marie T | Permit status: Completed | Permit id: 705633 | |||||
Zoning use permit Date: August 12, 2016 Client: Campanile Marie T | Permit status: Completed | Permit id: 705632 | |||||
Suppression permit Date: November 8, 2016 Client: Campanile Marie T | Permit status: Active | Permit id: 730125 | |||||
SCORE 96 Install 200amp panel,meter and service complete with grounding and install 51-outlets,38-switches,25-recessed lights,8-ceiling lights,3-ceiling fans,3-bathroom fans,4-outside lights,smokes and co detectors as per 2008 nec (east district) Date: March 16, 2017 Contractor: Allwire Electric Llc Client: Concrete Rose Development | Permit type: Electrical permit | Permit status: Completed | Completion date: November 8, 2017 | Permit id: 767137 | |||||
SCORE 100 Seal lateral and remove curb trap pa20161470768 (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: May 27, 2016 Contractor: Norman Cole Sr, Client: Concrete Rose Development | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 4, 2016 | Permit id: 695492 | |||||
SCORE 89 For the installation of an automatic sprinkler system with a new 1" combined fire and domestic line, for a new three-story single-family dwelling (above an existing foundation), installation in accordance with nfpa 13d. Date: November 8, 2016 Contractor: Aqueduct Fire Protection Client: Concrete Rose Development | Permit type: Suppression permit | Permit status: Completed | Completion date: November 9, 2017 | Permit id: 730125 | |||||
SCORE 82 For the erection of an attached three story building on an existing foundation. Structure to have a roof deck accessed by a roof deck access structure. Building to be fully sprinklered. All work to be done per approved plans. If field conditions var contact design professional prior to the start of any work. Separate permits required for mechanical, electrical, plumbing and fire suppression work. Date: August 8, 2016 Contractor: Mb Investment Group Llc Client: Concrete Rose Development | Permit type: New construction permit | Permit status: Completed | Completion date: November 9, 2017 | Permit id: 683198 | |||||
For the complete demolition of an existing attached structure. See a p no. 683203 for use. Date: August 12, 2016 Client: Concrete Rose Development | Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 12, 2016 | Permit id: 705632 | |||||
SCORE 82 To legalize the complete demolition of an attached three-story structure. Any deviation will require an amended building permit. Safety zone: 17 ft Date: August 12, 2016 Contractor: Mangual Demolition Inc Client: Concrete Rose Development | Permit type: Demolition permit | Permit status: Completed | Completion date: August 16, 2016 | Permit id: 705633 | |||||
SCORE 93 Installation of (1) hvac unit (including ductwork and all associated accessories). Sfd Date: March 20, 2017 Contractor: Angel Heating And Cooling Inc Client: Concrete Rose Development | Permit type: Mechanical permit | Permit status: Completed | Completion date: October 23, 2017 | Permit id: 767607 | |||||
SCORE 100 Lateral, 4" main sewer line, water serv pa20163641577 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection. & 1 1 2" bath rough in laundry, kitchen, new pex lines manifold the installation will comply with the philadelphia plumbing code 2004 Date: December 30, 2016 Contractor: Lawrence Caro Client: Concrete Rose Development | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 9, 2017 | Permit id: 747079 | |||||
SCORE 82 Interior demo of non-load bearing walls only,no structural work on this permit Date: March 17, 2016 Contractor: Riverfront Moving And Storage Client: Concrete Rose Development | Permit type: Demolition permit | Permit status: Completed | Completion date: May 4, 2017 | Permit id: 677108 |