Mechanical Date: November 29, 2001Permit status: Closed | Permit id: 01-05131 | |||||
Staten Client: Complaint - Staten | Permit type: Building enforcement | Permit status: Closed | Current use: Complaint-enforcement | Permit id: 13-00284 | Parcel: 9638 | |||||
January 10, 2013 5:28:12 pm pamk. Rswo, mother of tenant, underground oil tank, may have leak in tank, water getting into tank, copper piping running on top of ground from tank to house, hot water gas unit also has leaking issues. Pjk; february 13, 2013 2:36:15 pm pamk. Complaint inspection made at this address revealed several violations of the housing and building codes. They are as follows: (1) oil tank needs to have oil lines run from tank to house other than through fill tube. (2) fill tube and vent cap need to be repaired to keep water from entering oil tank. (3) requesting that a pressure test be performed on tank after corrections made to determine that tank is not leaking. (4) dryer vent is only run to crawl space and not to outside of house, needs to be corrected. (5) dug out portion of crawl space is taking on water when it rains and also the left side of the house at the crawl space has the footing completely undermined and will need to have an engineers evaluation and rep Permit type: Building enforcement | Permit status: Closed | Permit id: 13-00284 | Parcel: 9638 | |||||
Staten Date: September 28, 2015Client: Complaint - Staten | Permit type: Building enforcement | Permit status: Closed | Current use: Complaint-enforcement | Permit id: 13-00284 | Parcel: 9638 | |||||
SCORE 99 Comment date: thu nov 29 00:00: est 2001 - oil furnace with a/c in basement area by jsb via fax, donnie ball redacted phone number inspector fred mckenzie redacted phone number Date: November 29, 2001 Contractor: Ball Heating And Air ConditioninClient: Jim Williams | Permit type: Com: mechanical | Permit status: Closed | Current use: Commercial | Permit id: 01-05131 | Parcel: 9638 | |||||
January 10, 2013 5:28:12 pm pamk. Rswo, mother of tenant, underground oil tank, may have leak in tank, water getting into tank, copper piping running on top of ground from tank to house, hot water gas unit also has leaking issues. Pjk; february 13, 2013 2:36:15 pm pamk. Complaint inspection made at this address revealed several violations of the housing and building codes. They are as follows: (1) oil tank needs to have oil lines run from tank to house other than through fill tube. (2) fill tube and vent cap need to be repaired to keep water from entering oil tank. (3) requesting that a pressure test be performed on tank after corrections made to determine that tank is not leaking. (4) dryer vent is only run to crawl space and not to outside of house, needs to be corrected. (5) dug out portion of crawl space is taking on water when it rains and also the left side of the house at the crawl space has the footing completely undermined and will need to have an engineers evaluation and rep Date: September 28, 2015Permit type: Building enforcement | Permit status: Closed | Permit id: 13-00284 | Parcel: 9638 |