Electrical permit Date: June 13, 2012Client: Walter J Tilger Sm | Permit status: Completed | Permit id: 409689 | |||||
Electrical permit Date: June 13, 2012Client: Walter J Tilger S M | Permit status: Completed | Permit id: 409689 | |||||
SCORE 100 Remove faulty service entrance cables,2 gang meter socket,feeders to load centers. Install 200amp service with 3 gang meter socket,install new feeders and install house meter in garage, amps each panel,upgrade ground rod and cold water meter ground,grounding system on all 3 load center panels. Seperate common area lighting,outside security lighting,laundry room,and 2 garages to house panel,secure branch circuits hanging from garage ceiling,add gfci receptacles in laundry,remove unused cables Date: June 13, 2012 Contractor: Watts ElectricClient: Walter J Tilger S M | Permit type: Electrical permit | Permit status: Completed | Completion date: August 2, 2012 | Permit id: 409689 |