Building Permits at 45 Reddick Rd, Asheville, NC 28805


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with 45 Reddick Rd, Asheville, NC 28805 over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
Lot 6
Date:  April 17, 2006

Permit status: Closed | Permit id: 06-01323
2006/04/1709545 Reddick Rd, Asheville, Nc 28805
Date:  May 19, 2003

Permit status: Closed | Permit id: 03-01639
2003/05/1909545 Reddick Rd, Asheville, Nc 28805
Electrical
Date:  April 5, 2002

Permit status: Closed | Permit id: 02-01381
2002/04/0509545 Reddick Rd, Asheville, Nc 28805
Date:  December 11, 2001

Permit status: Closed | Permit id: 01-04847
2001/12/1109545 Reddick Rd, Asheville, Nc 28805
Date:  November 16, 2000

Permit status: Issued | Permit id: 00-05409
2000/11/1609545 Reddick Rd, Asheville, Nc 28805
Valley view mhp lot 14;tenant ardon; 5 15 03 12:23:55 pm; premise #redacted phone number6, ssb.; 5 19 03 11:36:29 am; valley view mobile home park, lot 14, ardon. Premise #redacted phone number6. Issued by ssb.; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final
Date:  May 19, 2003

Permit type: Permits - historical | Permit status: Closed | Permit id: 03-01639 | Parcel: 13918
2003/05/1909545 Reddick Rd, Asheville, Nc 28805
SCORE
77
Comment date: fri apr 05 00:00: est 2002 - lot 11/install heat pump by jsb from tim redacted phone number inspector alec arthur redacted phone number
Date:  April 5, 2002

Client: Tony Graham | Permit type: Com: mechanical | Permit status: Closed | Current use: Commercial | Permit id: 02-01380 | Parcel: 13918
2002/04/0507745 Reddick Rd, Asheville, Nc 28805Kaufman Mobile Home Supplies
SCORE
62
Comment date: mon nov 05 00:00: est 2001 - valley view mhp lot 15; comment date: wed jul 00:00: edt 2002 - lot 15/valley view mobile home park/jsb; comment date: mon nov 05 00:00: est 2001 - call gary
Date:  July 10, 2002
Value:   $5,000

Client: Valleyview Mhp Lot 15 | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 01-04814 | Parcel: 13918
2002/07/1050006245 Reddick Rd, Asheville, Nc 28805Manning John Robert Jr
SCORE
98
Comment date: fri jun 29 00:00: edt 2001 - valley view mhp lot 36; comment date: fri jun 29 00:00: edt 2001 - call gary stamey for building inspection at redacted phone number all subcontractors shall
Date:  July 3, 2001
Value:   $13,677

Client: Valley View Mh Park | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 01-02682 | Parcel: 13918
2001/07/03136779845 Reddick Rd, Asheville, Nc 28805Johnnys Mobile Home Service
SCORE
95
Comment date: fri nov 02 00:00: est 2001 - valley view mhp lot 24; comment date: wed jul 00:00: edt 2002 - lot 24/valley view mobile home park/jsb; comment date: fri nov 02 00:00: est 2001 - call gary
Date:  July 10, 2002
Value:   $32,100

Client: Valley View Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 01-04787 | Parcel: 13918
2002/07/10321009545 Reddick Rd, Asheville, Nc 28805Jerrys Heating And Air
Building enforcement

Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 02-00339s | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Building enforcement

Client: Lot 18 | Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 02-01546s | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Building enforcement

Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 02-01615s | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Building enforcement

Client: Lot 3 | Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 02-01461s | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Valley view mhp lot 36; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 01-02682 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Valley view mhp lot 24; lot 24/valley view mobile home park/jsb; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated wit

Permit type: Permits - historical | Permit status: Closed | Permit id: 01-04787 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Valley view mhp lot 15; lot 15/valley view mobile home park/jsb; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated wit

Permit type: Permits - historical | Permit status: Closed | Permit id: 01-04814 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Valley view mhp lot 17 14x80; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 01-04847 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Valley view mobile home park lot 15 debra ball black; added a mech permit for charles martin hyde who has installed a heat pump.; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same ele

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 00-04851 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Address is 6 reddick rd;mobile home; valley view mhp; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same electrical permit for set-up & air conditioner or heat pump, however a mechanic

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 03-00097 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Mobile home lot 13; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same electrical permit for set-up & air conditioner or heat pump, however a mechanical permit is required to assure sa

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 02-05701 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Valley view mobile home lot 29; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirti

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 03-01014 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Valley view mhp lot 14;tenant ardon; 5/15/03 12:23:55 pm; premise #redacted phone number6, ssb.; 5/19/03 11:36:29 am; valley view mobile home park, lot 14, ardon. Premise #redacted phone number6. Issued by ssb.; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water/waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final

Permit type: Permits - historical | Permit status: Closed | Permit id: 03-01639 | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Building enforcement

Permit status: In compliance | Permit id: 02-00339s | Parcel: 13918
09545 Reddick Rd, Asheville, Nc 28805
Building enforcement
Date:  March 21, 2002

Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 02-00339s | Parcel: 13918
2002/03/2109545 Reddick Rd, Asheville, Nc 28805
Building enforcement
Date:  February 3, 2003

Client: Lot 27 | Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 03-00168s | Parcel: 13918
2003/02/0309545 Reddick Rd, Asheville, Nc 28805
Lot 6
Date:  April 17, 2006
Value:   $12,000

Permit type: Historical | Permit status: Closed | Permit id: 06-01323
2006/04/17120009545 Reddick Rd, Asheville, Nc 28805
Historical
Date:  May 19, 2003
Value:   $15,000

Permit status: Closed | Permit id: 03-01639
2003/05/19150009545 Reddick Rd, Asheville, Nc 28805
Residential
Date:  March 13, 2003
Value:   $9,000

Permit status: Closed | Permit id: 03-00097
2003/03/1390009545 Reddick Rd, Asheville, Nc 28805
Residential
Date:  December 11, 2001
Value:   $25,000

Permit status: Closed | Permit id: 01-04847
2001/12/11250009545 Reddick Rd, Asheville, Nc 28805
Historical
Date:  July 10, 2002
Value:   $5,000

Permit status: Closed | Permit id: 01-04814
2002/07/1050009545 Reddick Rd, Asheville, Nc 28805
Residential
Date:  July 3, 2001
Value:   $13,677

Permit status: Closed | Permit id: 01-02682
2001/07/03136779545 Reddick Rd, Asheville, Nc 28805
Residential
Date:  November 16, 2000
Value:   $2,500

Permit status: Issued | Permit id: 00-05409
2000/11/1625009545 Reddick Rd, Asheville, Nc 28805
Residential
Date:  December 11, 2000
Value:   $34,549

Permit status: Closed | Permit id: 00-04851
2000/12/11345499545 Reddick Rd, Asheville, Nc 28805
Historical
Date:  July 10, 2002
Value:   $32,100

Permit status: Closed | Permit id: 01-04787
2002/07/10321009545 Reddick Rd, Asheville, Nc 28805
SCORE
69
Comment date: fri apr 05 00:00: est 2002 - wire new heat pump in lot 11 by jsb from tim redacted phone number inspector tim haynes redacted phone number
Date:  April 5, 2002

Client: Tony Graham | Permit type: Com: electrical | Permit status: Closed | Current use: Commercial | Permit id: 02-01381 | Parcel: 13918
2002/04/0506945 Reddick Rd, Asheville, Nc 28805Kaufman Supply Inc Of Fletcher
SCORE
86
Comment date: fri jun 29 00:00: edt 2001 - valley view mhp lot 36; comment date: fri jun 29 00:00: edt 2001 - call gary stamey for building inspection at redacted phone number all subcontractors shall
Date:  July 3, 2001
Value:   $13,677

Client: Valley View Mh Park | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 01-02682 | Parcel: 13918
2001/07/03136778645 Reddick Rd, Asheville, Nc 28805Grindstaff Electric
SCORE
69
Comment date: thu nov 16 00:00: est 20 - valley view mobile home park lot 15; comment date: thu nov 16 00:00: est 20 - manufacturers installation manual must be on site for inspection. Use their specs
Date:  June 3, 2015
Value:   $2,500

Client: Lot 15 Valley View Mhp | Permit type: Res: mfg. Home | Permit status: Expired | Current use: Residential | Permit id: 00-05409 | Parcel: 13918
2015/06/0325006945 Reddick Rd, Asheville, Nc 28805K And R Mobile Home Transporting
SCORE
98
Comment date: tue mar 11 00:00: est 2003 - valley view mobile home lot 29; comment date: tue mar 11 00:00: est 2003 - call gary stamey for building inspection at redacted phone number all subcontracto
Date:  March 13, 2003
Value:   $15,000

Client: Mobile Home | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 03-01014 | Parcel: 13918
2003/03/13150009845 Reddick Rd, Asheville, Nc 28805Johnnys Mobile Home Service
Valley view mhp lot 17 14x80; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting
Date:  December 11, 2001

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 01-04847 | Parcel: 13918
2001/12/1109545 Reddick Rd, Asheville, Nc 28805
SCORE
77
Comment date: thu mar 28 00:00: est 2002 - install heat pump at lot 11 by jsb from tim redacted phone number inspector alec arthur redacted phone number
Date:  March 28, 2002

Client: Tony Graham | Permit type: Com: mechanical | Permit status: Closed | Current use: Commercial | Permit id: 02-01259 | Parcel: 13918
2002/03/2807745 Reddick Rd, Asheville, Nc 28805Kaufman Mobile Home Supplies
SCORE
98
Comment date: wed jan 08 00:00: est 2003 - address is 6 reddick rd;mobile home; valley view mhp; comment date: wed jan 08 00:00: est 2003 - manufacturers installation manual must be on site for inspec
Date:  March 13, 2003
Value:   $9,000

Client: Valley View Mhp | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 03-00097 | Parcel: 13918
2003/03/1390009845 Reddick Rd, Asheville, Nc 28805Johnnys Mobile Home Service
Address is 6 reddick rd;mobile home; valley view mhp; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same electrical permit for set-up & air conditioner or heat pump, however a mechanic
Date:  March 13, 2003

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 03-00097 | Parcel: 13918
2003/03/1309545 Reddick Rd, Asheville, Nc 28805
Valley view mhp lot 36; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until
Date:  July 3, 2001

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 01-02682 | Parcel: 13918
2001/07/0309545 Reddick Rd, Asheville, Nc 28805
Mobile home lot 13; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same electrical permit for set-up & air conditioner or heat pump, however a mechanical permit is required to assure sa
Date:  January 22, 2003

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 02-05701 | Parcel: 13918
2003/01/2209545 Reddick Rd, Asheville, Nc 28805
SCORE
100
Comment date: wed jan 08 00:00: est 2003 - address is 6 reddick rd;mobile home; valley view mhp; comment date: wed jan 08 00:00: est 2003 - manufacturers installation manual must be on site for inspec
Date:  March 13, 2003
Value:   $9,000

Client: Valley View Mhp | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 03-00097 | Parcel: 13918
2003/03/13900010045 Reddick Rd, Asheville, Nc 28805Doug Grindstaff Elect Co Inc
Valley view mobile home lot 29; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirti
Date:  March 13, 2003

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 03-01014 | Parcel: 13918
2003/03/1309545 Reddick Rd, Asheville, Nc 28805
SCORE
76
Comment date: fri nov 02 00:00: est 2001 - valley view mhp lot 24; comment date: wed jul 00:00: edt 2002 - lot 24/valley view mobile home park/jsb; comment date: fri nov 02 00:00: est 2001 - call gary
Date:  July 10, 2002
Value:   $32,100

Client: Valley View Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 01-04787 | Parcel: 13918
2002/07/10321007645 Reddick Rd, Asheville, Nc 28805International Homes
Valley view mhp lot 15; lot 15 valley view mobile home park jsb; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated wit
Date:  July 10, 2002

Permit type: Permits - historical | Permit status: Closed | Permit id: 01-04814 | Parcel: 13918
2002/07/1009545 Reddick Rd, Asheville, Nc 28805
SCORE
95
Valley view mhp lot 24; comment date: wed jul 00:00: edt 2002 - lot 24 valley view mobile home park jsb; comment date: fri nov 02 00:00: est 2001 - call gary
Date:  July 10, 2002
Value:   $32,100

Client: Valley View Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 01-04787 | Parcel: 13918
2002/07/10321009545 Reddick Rd, Asheville, Nc 28805Jerrys Heating And Air
SCORE
84
Comment date: thu oct 12 00:00: edt 20 - valley view mobile home park lot 15 debra ball black; comment date: mon dec 11 00:00: est 20 - added a mech permit for charles martin hyde who has installed a
Date:  December 11, 2000
Value:   $34,549

Client: Black Mobile Home | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 00-04851 | Parcel: 13918
2000/12/11345498445 Reddick Rd, Asheville, Nc 28805Carolina Mountains Electric
SCORE
100
Comment date: mon nov 05 00:00: est 2001 - valley view mhp lot 15; comment date: wed jul 00:00: edt 2002 - lot 15/valley view mobile home park/jsb; comment date: mon nov 05 00:00: est 2001 - call gary
Date:  July 10, 2002
Value:   $5,000
Contractor: T.K. Electric

Client: Valleyview Mhp Lot 15 | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 01-04814 | Parcel: 13918
2002/07/10500010045 Reddick Rd, Asheville, Nc 28805T.K. Electric
SCORE
98
Comment date: thu oct 12 00:00: edt 20 - valley view mobile home park lot 15 debra ball black; comment date: mon dec 11 00:00: est 20 - added a mech permit for charles martin hyde who has installed a
Date:  December 11, 2000
Value:   $34,549
Contractor: Nathans Transport

Client: Black Mobile Home | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 00-04851 | Parcel: 13918
2000/12/11345499845 Reddick Rd, Asheville, Nc 28805Nathans Transport
SCORE
62
Comment date: wed nov 07 00:00: est 2001 - valley view mhp lot 17 14x80; comment date: wed nov 07 00:00: est 2001 - call gary stamey for building inspection at redacted phone number all subcontractors
Date:  December 11, 2001
Value:   $25,000

Client: Valley View Mhp Lot 17 | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 01-04847 | Parcel: 13918
2001/12/11250006245 Reddick Rd, Asheville, Nc 28805Manning John Robert Jr
SCORE
100
Comment date: wed nov 07 00:00: est 2001 - valley view mhp lot 17 14x80; comment date: wed nov 07 00:00: est 2001 - call gary stamey for building inspection at redacted phone number all subcontractors
Date:  December 11, 2001
Value:   $25,000
Contractor: T.K. Electric

Client: Valley View Mhp Lot 17 | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 01-04847 | Parcel: 13918
2001/12/112500010045 Reddick Rd, Asheville, Nc 28805T.K. Electric
SCORE
69
Comment date: thu mar 28 00:00: est 2002 - to wire heat pump by jsb from tim redacted phone number inspector tim haynes redacted phone number
Date:  March 28, 2002

Client: Tony Graham | Permit type: Com: electrical | Permit status: Closed | Current use: Commercial | Permit id: 02-01260 | Parcel: 13918
2002/03/2806945 Reddick Rd, Asheville, Nc 28805Kaufman Supply Inc Of Fletcher
Valley view mobile home park lot 15 debra ball black; added a mech permit for charles martin hyde who has installed a heat pump.; manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated with heat tape. Do not attach skirting until final inspection has been made. Assure electrical permit is activated. Can use same ele
Date:  December 11, 2000

Permit type: Res: mfg. Home | Permit status: Closed | Permit id: 00-04851 | Parcel: 13918
2000/12/1109545 Reddick Rd, Asheville, Nc 28805
SCORE
98
Comment date: tue dec 17 00:00: est 2002 - mobile home lot 13; comment date: tue dec 17 00:00: est 2002 - manufacturers installation manual must be on site for inspection. Use their specs on pier and
Date:  January 22, 2003
Value:   $15,000

Client: Lot 13 | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 02-05701 | Parcel: 13918
2003/01/22150009845 Reddick Rd, Asheville, Nc 28805Johnnys Mobile Home Service
SCORE
98
Comment date: tue dec 17 00:00: est 2002 - mobile home lot 13; comment date: tue dec 17 00:00: est 2002 - manufacturers installation manual must be on site for inspection. Use their specs on pier and
Date:  January 22, 2003
Value:   $15,000
Contractor: Tbd Pl

Client: Lot 13 | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 02-05701 | Parcel: 13918
2003/01/22150009845 Reddick Rd, Asheville, Nc 28805Tbd Pl
SCORE
100
Comment date: tue mar 11 00:00: est 2003 - valley view mobile home lot 29; comment date: tue mar 11 00:00: est 2003 - call gary stamey for building inspection at redacted phone number all subcontracto
Date:  March 13, 2003
Value:   $15,000

Client: Mobile Home | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 03-01014 | Parcel: 13918
2003/03/131500010045 Reddick Rd, Asheville, Nc 28805Doug Grindstaff Elect Co Inc
SCORE
93
Comment date: tue apr 22 00:00: edt 2003 - valley view mhp lot 14;tenant ardon; comment date: thu may 15 00:00: edt 2003 - 5/15/03 12:23:55 pm; premise #redacted phone number6, ssb.; comment date: mon
Date:  May 19, 2003
Value:   $15,000

Client: Valley View Mhp Lot 14 | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 03-01639 | Parcel: 13918
2003/05/19150009345 Reddick Rd, Asheville, Nc 28805American Mobile Home Movers
SCORE
98
Comment date: tue apr 22 00:00: edt 2003 - valley view mhp lot 14;tenant ardon; comment date: thu may 15 00:00: edt 2003 - 5/15/03 12:23:55 pm; premise #redacted phone number6, ssb.; comment date: mon
Date:  May 19, 2003
Value:   $15,000

Client: Valley View Mhp Lot 14 | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 03-01639 | Parcel: 13918
2003/05/19150009845 Reddick Rd, Asheville, Nc 28805Carolina Mountain Enterprises
SCORE
70
Comment date: thu oct 12 00:00: edt 20 - valley view mobile home park lot 15 debra ball black; comment date: mon dec 11 00:00: est 20 - added a mech permit for charles martin hyde who has installed a
Date:  December 11, 2000
Value:   $34,549

Client: Black Mobile Home | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 00-04851 | Parcel: 13918
2000/12/11345497045 Reddick Rd, Asheville, Nc 28805Martin Hyde Mechanical Contrac
SCORE
77
Comment date: wed nov 07 00:00: est 2001 - valley view mhp lot 17 14x80; comment date: wed nov 07 00:00: est 2001 - call gary stamey for building inspection at redacted phone number all subcontractors
Date:  December 11, 2001
Value:   $25,000

Client: Valley View Mhp Lot 17 | Permit type: Res: mfg. Home | Permit status: Closed | Current use: Residential | Permit id: 01-04847 | Parcel: 13918
2001/12/11250007745 Reddick Rd, Asheville, Nc 28805Kaufman Mobile Home Supplies
Valley view mhp lot 24; lot 24 valley view mobile home park jsb; call gary stamey for building inspection at redacted phone number all subcontractors shall contact building safety (redacted phone number) to activate electrical, plumbing & mechanical permits. Manufacturers installation manual must be on site for inspection. Use their specs on pier and anchor strap spacing if manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. If more than 25% of unit is over 3 above grade then tie-downs & pier spacing to be designed by engineer. Stairs required at exists. Water and waste lines properly supported. Building "final" includes water waste lines hook-ups. It is recommended that water lines be insulated wit
Date:  July 10, 2002

Permit type: Permits - historical | Permit status: Closed | Permit id: 01-04787 | Parcel: 13918
2002/07/1009545 Reddick Rd, Asheville, Nc 28805
SCORE
100
Comment date: fri nov 02 00:00: est 2001 - valley view mhp lot 24; comment date: wed jul 00:00: edt 2002 - lot 24/valley view mobile home park/jsb; comment date: fri nov 02 00:00: est 2001 - call gary
Date:  July 10, 2002
Value:   $32,100

Client: Valley View Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 01-04787 | Parcel: 13918
2002/07/103210010045 Reddick Rd, Asheville, Nc 28805Tim Howell Electrical Services
SCORE
56
March 21, 2006 12:57:04 pm scarver mobile home moving lot 6-valley view park;scc; park, known as valley view manufactured home park, is located in rm-8 multi-family medium density district, manufactured housing community overlay (mhc-o), manufactured housing overlay (mh-o) and blue ridge parkway overlay district. Zoning permit and site plan approved for replacement of same size unit on lot # 6. Setbacks measured from perimeter boundary. Blue ridge parkway overlay district is created to protect and preserve the unique features of this asset to the city and region. Standards established in this district are to protect the scenic quality of the blue ridge parkway and reduce encroachment on its rural setting. In accordance with udo, sec. 7-9-6. Blue ridge parkway overlay district, principal buildings and structures to be located adjacent to the blue ridge parkway shall have a minimum setback of feet from the edge of property owned by the united states government and
Date:  April 17, 2006
Value:   $12,000

Client: Lot 6 | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 06-01323 | Parcel: 13918
2006/04/17120005645 Reddick Rd, Asheville, Nc 28805Johnny Franklin Moving
BEST LOCAL CONTRACTORS




Contractor Rank Contractor Details Number of Projects Avg. Project Cost Years in Business Photos
Need a Contractor ?
Just fill out a form below and get several free quotes from best local contractors in your area.