Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 91 Plumbing ![]() ![]() Permit status: Permit issued | Permit id: 20062642001 | |||||
SCORE 84 Alteration ![]() ![]() Permit status: Permit issued | Permit id: 20062642001 | |||||
SCORE 92 ![]() ![]() Client: Vincent Di Napoli | Client Address: 645 Bx River Road Yonkers Ny 10704 | Client Phone: (718) 237-6700 | Client Company: Vlj Construction Corp | Permit status: Initial | Permit id: 200626420 | |||||
SCORE 100 ![]() ![]() Client: Vincent Di Napoli | Client Address: 645 Bx River Road Yonkers Ny 10704 | Client Phone: (718) 237-6700 | Client Company: Vlj Construction Corp | Permit status: Initial | Permit id: 200626420 | |||||
SCORE 100 Plumbing ![]() ![]() Permit status: Permit issued | Permit id: 22057747201 | |||||
Public area: at basement.(boiler room) clear main sewer house trap from trap to street and from house trap into bldg. Pump out all stagnant water ![]() Permit type: Stopag | Permit id: Eh12504 | |||||
Apt 2, bathroom trace, locate and repair concealed water leak from above. Repair with similar materials for approximate 15 s. F. Of ceiling as a re ![]() Permit type: Gc | Permit id: Ee08540 | |||||
At basement- at boiler room: make all necessary repairs to gallon hw heater in order to restore hot water to apt #2. There are 3 boilers and 3 hw t ![]() Permit type: Heat | Permit id: Ef11687 | |||||
At apt. 2, basement --- remove and replace existing leaking hot water heater with new gallons gas hot water heater including all plumbing connec ![]() Permit type: Heat | Permit id: Ed13222 | |||||
At basement- at boiler room:provide / install four thermocoupling and two gas valves and make all necessary repairs to 2nd. And 3rd. Floor gas boilers ![]() Permit type: Heat | Permit id: Ef12694 | |||||
At basement- at boiler room:provide install four thermocoupling and two gas valves and make all necessary repairs to 2nd. And 3rd. Floor gas boilers ![]() Permit type: Heat | Permit id: Ef12694 | |||||
Apartment #1, bathroom: trace & repair the source of concealed water leaks from the ceiling. Repair with similar materials the defective plaster ![]() Permit type: Gc | Permit id: Ee11525 | |||||
At basement , trace and repair the water leak from above (possible bathroom leak). Replace approx. Sq. Ft. Of ceiling with new green g. W. B. Tape a ![]() Permit type: Gc | Permit id: Ef12932 | |||||
At basement- at boiler room; make all necessary repairs to heating equipment in order for con ed to restore gas service to the apt. Heating equipment ![]() Permit type: Heat | Permit id: Ef12935 | |||||
At basement. At the gas meter bank: remove all illegal connections and make the necessary repairs to the gas meter bank as per dob and con ed re ![]() Permit type: Plumb | Permit id: Eh01583 | |||||
Three units - no heat ; hot water & cooking gas - building wide . Individual gas boilers (3)& hot water heaters(3).- gas service off due to safety ![]() Permit type: Plumb | Permit id: Eh05303 | |||||
Three units : no heat ; hot water & cooking gas building wide . Individual gas boilers (three) & hot water heaters ( three) . Gas service off d ![]() Permit type: Plumb | Permit id: Eh07123 | |||||
At basement apt. Heat related hot water circulating heating system troubleshoot leak in the hot water circulating heating system through o ![]() Permit type: Plumb | Permit id: Eh14256 | |||||
Heat and hot water related matter at basement apt ----- trace and repair concealed water leak at basement apt and restore cold water sypply in Permit type: Plumb | Permit id: Eh10905 | |||||
Heat and hot water related matter at basement apt ----- trace and repair concealed water leak at basement apt and restore cold water sypply in ![]() Permit type: Plumb | Permit id: Eh10905 | |||||
At basement in the boiler room heat related trace and properly repair and restore electric supply to the boiler supplying heat to the 1s ![]() Permit type: Elec | Permit id: Eh14255 |