| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
SCORE 91 Replace existing 3 porches with one new steel porch and two wood porches Permit type: Permit - renovation/ | Permit id: 100351782 | |||||
SCORE 95 1st reinstatement of permit # 100351782 issued 12 3 2010 for 25% of the original cost 50 and change the gc to (f) knight construction, llc. Permit type: Permit - reinstate r | Permit id: 100427326 | |||||
SCORE 100 Replace bad service, switch for breaker Value: $850 Contractor: Alex's ElectricPermit type: Permit - electric wi | Permit id: 100431100 | |||||
Replace 40' of 4"" cast iron in basement (exposed) in unit a.",13-27-221-037-0001,,,,,owner as general contractor,wellington pulaski condo asso,2954 n. Pulaski rd.,chicago,il,60641,expeditor,anthony ortiz,2026 w. Webster ave. Floor 3rd,chicago,il,60647,(312)493-8340,contractor-plumber plumbing,"zuniga's plumbing, inc. Date: February 4, 2013 Value: $500Permit type: Permit - easy permit | Permit id: 100476587 | |||||
SCORE 100 Violation number 9969681load calculation service size 120 208v, 400a overhead, 3ph 4wire1set400kcmil there 250kcmil for newtal thwn co. In one3 rmc pipe ampacity for newtral 200a (800x70%=760a:3=253. 3a(250mcm thwnco. Has 255a total 18meters in 2groups 8meters at 4007 basement,10metersat 4005 basement service disconnect(ocp for feeders)-1breaker 400a bld area outside (irregular 3 levels):residential 11,500 sq ft, Permit type: Permit - electric wi | Permit id: 100586536 | |||||
SCORE 56 Replace of 4" cast iron in basement (exposed) in unit a. Permit type: Permit - easy permit process | Permit id: 100476587 | |||||
SCORE 100 Violation number 9969681load calculation service size 120 208v, 400a overhead, 3ph 4wire1set400kcmil there 250kcmil for newtal thwn co. In one3 rmc pipe ampacity for newtral 200a+(800x70%=760a:3=253. 3a(250mcm thwnco. Has 255a total 18meters in 2groups 8meters at 4007 basement,10metersat 4005 basement service disconnect(ocp for feeders)-1breaker 400a bld area outside (irregular 3 levels):residential 11,5 sq ft, Permit type: Permit - electric wiring | Permit id: 100586536 | |||||
SCORE 95 1st reinstatement of permit # 100351782 issued 12 3 20 for 25% of the original cost + and change the gc to (f) knight construction, llc. Permit type: Permit - reinstate revoked pmt | Permit id: 100427326 | |||||
SCORE 72 Building code violations, interior alterations, new partitions & drywall repair, new drainage lines for drip pans for furnaces, new screen doors for residential units, new basement doors, spot tuckpointing, replace broke glass blocks in windows & repair limestone sills (address code violations# 10352723 & 10917129) per plans certified plans corrections: conditional permit subject to field inspections Permit type: Permit - renovation/alteration | Permit id: 100521258 | |||||
SCORE 95 Replace bad service, switch for breaker Value: $850 Contractor: Alexs ElectricPermit type: Permit - electric wiring | Permit id: 100431100 |