Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Demolish existing commercial building at 2101 9th ave, per plan - review with 6424554 Date: March 16, 2015 Applicant: Patterson-Ohare, Jodi | Permit type: Demolition | Permit status: Permit issued | Current use: Commercial | Permit id: 6424555 | |||||
Phased project: construction of a residential high rise building with retail at grade and below grade parking and occupy, per plan Date: September 18, 2014 Value: $92,980,518 Applicant: Patterson-Ohare, Jodi | Permit type: Construction | Permit status: Application accepted | Current use: Commercial | Permit id: 6387467 | |||||
Shoring and excavation only to prepare site for future construction of hi-rise mixed use residential building with underground parking, per mup 3016305 and per plans. Date: September 16, 2014 Value: $5,030,000 Applicant: Patterson-Ohare, Jodi | Permit type: Construction | Permit status: Application accepted | Current use: Commercial | Permit id: 6424553 | |||||
Demolish existing commercial building at 2101 9th ave, per plan - review with 6424554 Date: March 16, 2015 Applicant: Patterson-Ohare, Jodi | Permit type: Demolition | Permit status: Permit issued | Current use: Commercial | Permit id: 6424555 | |||||
Phased project: construction of a residential high rise building with retail at grade and below grade parking and occupy, per plan Date: September 18, 2014 Value: $92,980,518 Applicant: Patterson-Ohare, Jodi | Permit type: Construction | Permit status: Permit issued | Current use: Commercial | Permit id: 6387467 | |||||
Phased project: construction of a residential high rise building with retail at grade and below grade parking and occupy, per plan Date: August 24, 2015 Value: $114,057,844 Applicant: Patterson-Ohare, Jodi | Permit type: Construction | Permit status: Permit issued | Expiration date: February 24, 2017 | Current use: Commercial | Permit id: 6387467 | |||||
SCORE 100 Sensor in parking garage job #830678 Date: December 16, 2015 Contractor: E C Company Permit type: Electrical | Permit status: Permit issued | Expiration date: December 15, 2016 | Current use: Commercial | Permit id: 6509970 | |||||
SCORE 95 Day get started to be on site for branch circuits only, plan review permit under #6481553 Date: October 30, 2015 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit closed | Completion date: November 16, 2015 | Expiration date: November 30, 2015 | Current use: Commercial | Permit id: 6502760 | |||||
SCORE 95 Cec job# 500223-3: 80a feed from existing panel Date: March 23, 2015 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit closed | Completion date: March 30, 2015 | Expiration date: March 22, 2016 | Current use: Commercial | Permit id: 6465159 | |||||
SCORE 95 Job# 504098-1: demo (2) circuits & outlets Date: December 5, 2014 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit closed | Completion date: October 29, 2015 | Expiration date: December 5, 2015 | Current use: Commercial | Permit id: 6449329 | |||||
SCORE 95 Add facp to monitor sprinkler system & provide off-site monitoring. Joint venture with federal fire safety & pride electric Date: January 25, 2005 Contractor: Pride Electric Incorporated Permit type: Electrical | Permit status: Permit finaled | Completion date: June 28, 2005 | Expiration date: January 25, 2006 | Current use: Commercial | Permit id: 6050516 | |||||
SCORE 95 Install low voltage alarm Date: November 12, 2002 Contractor: Adt Security Services Inc Permit type: Electrical | Permit status: Permit finaled | Completion date: December 19, 2002 | Expiration date: November 12, 2003 | Current use: Commercial | Permit id: 6006693 | |||||
Land use application to allow a 41-story, 4 unit residential building with 8,284 sq. Ft. Of retail at grade. Parking for 238 vehicles will be located below grade. Review includes demolition of 17,811 sq. Ft. Of existing structure. Date: March 24, 2015 Value: $100,000,000 Applicant: Ninth And Lenora Llc, | Permit type: Design review with edg, sepa threshold determination | Permit status: Permit issued | Current use: Commercial | Permit id: 3016305 | |||||
SCORE 95 New installation Date: July 15, 2016 Contractor: Kone Inc Applicant: Kone Inc | Permit type: Conveyance | Permit status: Permit issued | Expiration date: January 15, 2018 | Permit id: 6544672 | |||||
SCORE 95 Stand alone sprinkler install fire sprinkler and standpipe systems throughout (43) story high-rise bldg with (6) levels below grade Date: May 6, 2016 Contractor: Patriot Fire Protection Inc Applicant: Dacca, John | Permit type: Mechanical | Permit status: Permit issued | Expiration date: November 6, 2017 | Current use: Commercial | Permit id: 6521880 | |||||
SCORE 95 Installing door detector Date: March 27, 2014 Contractor: Otis Elevator Company Applicant: Otis Elevator Company | Permit type: Conveyance | Permit status: Permit closed | Completion date: March 27, 2014 | Expiration date: September 27, 2015 | Permit id: 6307572 | |||||
SCORE 95 507092 - install cat 5 cabling to 33 locations from floors 1-2. Install cat 5 cable to 78 locations in the parking garage. Install cat 5 cable to 1783 locations from floors 3-42, install backbone cabling from demarc to each idf. Date: November 3, 2016 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit issued | Expiration date: November 3, 2017 | Current use: Commercial | Permit id: 6565258 | |||||
SCORE 95 (2) dx split systems and (4) vrf heat pumps serving 27 fan coil units Date: October 26, 2016 Contractor: Macdonaldmiller Service Inc Applicant: Macdonald-Miller Service Inc | Permit type: Refrigeration | Permit status: Permit issued | Expiration date: April 26, 2018 | Current use: Commercial | Permit id: 6563807 | |||||
SCORE 95 Install sanitary side sewer laterals & connect to existing 18" main; assoc bldg permit 6387467. Date: February 9, 2015 Contractor: Gary Merlino Construction Co Applicant: Gary Merlino Construction Co | Permit type: Side sewer | Permit status: Permit issued | Expiration date: August 9, 2016 | Current use: Commercial | Permit id: 6458541 | |||||
SCORE 95 505213 - (1) amp, 1 volt circuit to the controller. (1) 3 wire, 24v electrical connection to the trash chute controller on each floor. Floors Date: January 24, 2017 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit issued | Expiration date: January 24, 2018 | Current use: Commercial | Permit id: 6577680 | |||||
SCORE 95 Installation of (1) illuminated canopy sign for stratus Applicant: Western Neon Inc | Permit type: Sign/billboard/awning | Permit status: Permit issued | Expiration date: March 14, 2019 | Current use: Commercial | Permit id: 6618322 | |||||
SCORE 95 Alteration; rear cop, add camera, car b Applicant: Kone Inc | Permit type: Conveyance | Permit status: Application accepted | Permit id: 6634710 | |||||
SCORE 95 Alteration; rear cop, add camera, car a Applicant: Kone Inc | Permit type: Conveyance | Permit status: Application accepted | Permit id: 6634711 | |||||
SCORE 95 Alteration; rear cop, add camera, car d Applicant: Kone Inc | Permit type: Conveyance | Permit status: Application accepted | Permit id: 6634708 | |||||
SCORE 86 Install a new expansion tank Date: July 17, 2017 Contractor: Macdonald Miller Fac Sol Inc Applicant: Macdonald/miller Fac Sol Inc | Permit type: Boiler / pressure vessel | Permit status: Permit closed | Completion date: October 16, 2017 | Expiration date: January 17, 2019 | Current use: Commercial | Permit id: 6606986 | |||||
SCORE 86 Install a new hot water storage tank Date: July 17, 2017 Contractor: Macdonald Miller Fac Sol Inc Applicant: Macdonald/miller Fac Sol Inc | Permit type: Boiler / pressure vessel | Permit status: Permit closed | Completion date: October 16, 2017 | Expiration date: January 17, 2019 | Current use: Commercial | Permit id: 6606987 | |||||
SCORE 86 Install a new boiler Date: July 17, 2017 Contractor: Macdonald Miller Fac Sol Inc Applicant: Macdonald/miller Fac Sol Inc | Permit type: Boiler / pressure vessel | Permit status: Permit closed | Completion date: October 16, 2017 | Expiration date: January 17, 2019 | Current use: Commercial | Permit id: 6606988 | |||||
SCORE 86 Install a new hydropneumatic tank Date: July 17, 2017 Contractor: Macdonald Miller Fac Sol Inc Applicant: Macdonald/miller Fac Sol Inc | Permit type: Boiler / pressure vessel | Permit status: Permit closed | Completion date: October 16, 2017 | Expiration date: January 17, 2019 | Current use: Commercial | Permit id: 6606914 | |||||
SCORE 95 Temp use Date: July 19, 2017 Contractor: Kone Inc Applicant: Kone Inc | Permit type: Conveyance | Permit status: Permit closed | Completion date: November 20, 2017 | Expiration date: January 19, 2019 | Permit id: 6607695 | |||||
SCORE 95 Wall panels, ceiling, lighting, handrails Applicant: Vertical Dimensions Llc | Permit type: Conveyance | Permit status: Permit closed | Completion date: November 20, 2017 | Expiration date: April 12, 2019 | Permit id: 6621241 | |||||
SCORE 95 Day get started to be on site for fire alarm only, plan review permit under #3515381 joint venture between simplexgrinnell & cochran inc. 2/10/16 sk renewal. 3/29/2016 paf renewal Date: January 25, 2016 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit issued | Expiration date: April 25, 2016 | Current use: Commercial | Permit id: 6515385 | |||||
SCORE 95 J# 506745install access control system enclosures, power supplies, circuit boards, and devices. Perform connections for electric locks. Install surveillance system server, power supplies, and network cameras. Run associated security cable to respective idf. 120vac connections by others. 13 power supplies, 37 circuit boards, 254 access control devices, 61 cameras. Floors p6, p5, p4, p3, p2, p1, p1a, 1a, 1, 2, 3, 4, 5, 6, r1. Burt maxwell, 206-963-3517 Date: March 6, 2017 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit issued | Expiration date: March 6, 2018 | Current use: Commercial | Permit id: 6584547 | |||||
SCORE 95 Temporary use (car a) Date: September 19, 2017 Contractor: Kone Inc Applicant: Kone Inc | Permit type: Conveyance | Permit status: Permit closed | Completion date: November 20, 2017 | Expiration date: March 19, 2019 | Permit id: 6619196 | |||||
SCORE 95 11 30 2017 - cancelled customer log #17-1476(2) split system and heat pumps serving fan coils units Date: September 1, 2016 Contractor: Macdonaldmiller Service Inc Applicant: Macdonald-Miller Service Inc | Permit type: Refrigeration | Permit status: Permit issued | Expiration date: March 1, 2018 | Current use: Commercial | Permit id: 6554534 | |||||
SCORE 95 Provide temporary power for excavators, tower cranes, man-lifts, dewtering, lighting, tools, etc. Associated construction permit #6387467 (not yet issued) and demo permit (issued) #6424555. 3 1 2016 paf- permit renewed to 4 23 2017 per e-mail request. 5 3 17 sk renewal Permit type: Electrical | Permit status: Permit issued | Expiration date: April 23, 2017 | Current use: Commercial | Permit id: 6450833 | |||||
SCORE 95 Temporary use (car b) Date: September 19, 2017 Contractor: Kone Inc Applicant: Kone Inc | Permit type: Conveyance | Permit status: Permit closed | Completion date: November 20, 2017 | Expiration date: March 19, 2019 | Permit id: 6619195 | |||||
SCORE 95 225 of heat trace, (5) 30amp circuits for heat trace controllers Date: September 29, 2017 Contractor: Macdonaldmiller Service Inc Permit type: Electrical | Permit status: Permit closed | Completion date: December 4, 2017 | Expiration date: September 29, 2018 | Current use: Commercial | Permit id: 6621709 | |||||
SCORE 95 Closed as incomplete - expired permit. Temp dewatering; bldg permit 6424553. Date: March 30, 2015 Contractor: Sellen Construction Co Inc Applicant: Sellen Construction Co Inc | Permit type: Side sewer | Permit status: Permit issued | Expiration date: September 30, 2017 | Current use: Commercial | Permit id: 6466361 | |||||
SCORE 95 Alteration; rear cop, add camera, car c Applicant: Kone Inc | Permit type: Conveyance | Permit status: Application accepted | Permit id: 6634709 | |||||
SCORE 95 Installing a new boiler Date: August 10, 2017 Contractor: Macdonaldmiller Service Inc Applicant: Macdonald-Miller Service Inc | Permit type: Boiler / pressure vessel | Permit status: Permit closed | Completion date: October 16, 2017 | Expiration date: February 10, 2019 | Current use: Commercial | Permit id: 6611396 | |||||
SCORE 95 Shoring and excavation only to prepare site for future construction of hi-rise mixed use residential building with underground parking, per mup 3016305 and per plans. Applicant: Patterson-Ohare, Jodi | Permit type: Construction | Permit status: Permit issued | Expiration date: November 22, 2016 | Current use: Commercial | Permit id: 6424553 | |||||
SCORE 100 Ddc control work through out the building job # 830678 9 29 17 hkh; renew Date: November 2, 2016 Contractor: E C Company Permit type: Electrical | Permit status: Permit issued | Completion date: December 1, 2017 | Expiration date: November 2, 2017 | Current use: Commercial | Permit id: 6565064 | |||||
SCORE 95 11 30 2017 - cancelled customer log #17-1477installing a new expansion tank Date: August 30, 2017 Contractor: Macdonaldmiller Service Inc Applicant: Macdonald-Miller Service Inc | Permit type: Boiler / pressure vessel | Permit status: Permit issued | Expiration date: February 28, 2019 | Current use: Commercial | Permit id: 6614988 | |||||
SCORE 95 Furnish and install all required electrical systems for new apartment tower. 10 19 2016 paf renew. 11 29 16 jcb; revision submitted for approval to add a service rated lockable disconnect ahead of the meters, increase in job value of 4,000. 00. 10 31 17 cep; renew. Permit type: Electrical | Permit status: Permit issued | Expiration date: November 13, 2016 | Current use: Commercial | Permit id: 6481553 | |||||
SCORE 95 Wall panels, ceiling, lighting, handrails Applicant: Vertical Dimensions Llc | Permit type: Conveyance | Permit status: Permit closed | Completion date: November 20, 2017 | Expiration date: April 12, 2019 | Permit id: 6621243 | |||||
SCORE 95 11 30 2017 - cancelled customer log #17-1478 8 of heat trace , 9 t stats , power by cochran. Date: September 12, 2016 Contractor: Macdonaldmiller Service Inc Permit type: Electrical | Permit status: Permit issued | Expiration date: September 12, 2017 | Current use: Commercial | Permit id: 6556022 | |||||
SCORE 95 Install mh structure w pump; connect to ex. Cb in street. Connection approved by spu. Associated demolition permit 6590907. Date: November 15, 2017 Contractor: Gary Merlino Construction Co Applicant: Gary Merlino Construction Co | Permit type: Side sewer | Permit status: Permit issued | Expiration date: May 15, 2019 | Current use: Commercial | Permit id: 6630576 | |||||
SCORE 95 Install new fire alarm system. Joint venture between simplexgrinnell & cochran inc. 5 3 17 paf renew Date: April 12, 2016 Contractor: Cochran Incorporated Permit type: Electrical | Permit status: Permit issued | Completion date: November 27, 2017 | Expiration date: April 12, 2017 | Current use: Commercial | Permit id: 6515381 | |||||
SCORE 100 Install low voltage alarm system 11 17 05 cw - about to expire letter sent. Date: January 5, 2005 Contractor: Froula Alarm Systems Inc Permit type: Electrical | Permit status: Permit finaled | Completion date: December 1, 2005 | Expiration date: January 5, 2006 | Current use: Commercial | Permit id: 6049468 | |||||
SCORE 89 Renovation of a gallery area in an existing sfr 12 16 04 jcb: changed occupany from sf r to cmrcl. Date: December 13, 2004 Contractor: Miller Electric Incorporated Permit type: Electrical | Permit status: Permit closed | Completion date: October 28, 2009 | Expiration date: December 13, 2005 | Current use: Commercial | Permit id: 6048332 | |||||
SCORE 95 Installing a new expansion tank. Date: September 22, 2017 Contractor: Macdonaldmiller Service Inc Applicant: Macdonald-Miller Service Inc | Permit type: Boiler / pressure vessel | Permit status: Permit closed | Completion date: October 16, 2017 | Expiration date: March 22, 2019 | Current use: Single family / duplex | Permit id: 6618455 |