ACTIVITY
PERMITS VALUATION
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
SCORE 56 Number of borings = 11 type of borings = geotechnical diameter = 8" depth = feet drilling method = hollow stem auger Date: April 20, 2015 Contractor: Edward DaltonClient: Riggs Investment Inc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500261 | |||||
SCORE 56 Proposed field activities include hollow-stem auger soil sampling and groundwater monitoring well installation and sampling. All locations proposed for soil borings will be cleared to 8 ft bgs using soft-dig methods such as a hand augering to avoid contacting utilities or other underground structures. Five soil borings will be advanced to ft bgs or refusal, whichever is shallower. At least three of the proposed soil borings will be converted to permanent groundwater monitoring wells. Date: April 14, 2016Client: Rainier Viera - Chevron Environmental Management Company | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1600177 | |||||
SCORE 56 A total of 5 borings will be completed utilizing a geoprobe direct push drill rig using a dual tube sampling device. The borings will create a 2. 25-inch annulus. All 5 geoprobe borings will be completed to a depth of feet below ground surface. Additionally, three borings will be completed utilizing a hollow-stem auger drill rig using a split spoon sampling device. The borings will create a 6-inch annulus. All 3 hollow-stem borings will be completed to a depth of 25 feet below ground surface. Following completion, borings will be tremme grouted from the bottom to top using a mixture of powdered bentonite and potable water per doee recommendation. Date: March 17, 2017 Contractor: James BrawnerClient: James Brawner | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700198 | |||||
SCORE 67 Installing 3 soil vapor sampling points on private property, via air knife and/or hand auger, as part of a vapor intrusion investigation. Points will be sampled periodically. Date: October 13, 2016 Contractor: Rainier Viera; Lauren VogelClient: Rainier Viera | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700005 | |||||
SCORE 59 We will perform a total of three geotechnical borings on the proposed site which will be extended to depths of 25 feet and feet below existing site grades. The borings will be located within the bounds of the private property. The borings will be drilled utilizing 3. 25-inch hollow stem, continuous flight augers. The borings will be performed utilizing a truck-mounted drill rig and will generate an approximate 6-inch annulus. After geotechnical exploration is complete, the borings will be backfilled in accordance with ddoe requirements with bentonite slurry, which has a consistency of two pounds bentonite powder to one gallon water. Date: June 29, 2017 Contractor: Mariamawit BorgaClient: Brittany Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700352 |