| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
New construction of 576 s. F. Open air pavilion with picnic tables for student use on school campus. No e, m, p involved. Date: June 8, 2015 Value: $37,000Applicant: Chad Danos | Permit type: Commercial: new | Permit id: 49417 | |||||
SCORE 63 New construction of 576 s. F. Open air pavilion with picnic tables for student use on school campus. No e, m, p involved. Applicant: Chad Danos | Permit type: Commercial: new | Permit id: 49417 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall up to 4, electrical fixtures and fuses and some plumbing fixtures. This permit is for the 10,2 s. F. Theater building. This building received 40" of water. Electrical panels will be inspected by an electrician. Water closets and lavatories will also be reinstalled in this permit. There is a 2hr fire rated wall and curtain along the stage. 1hr rated wall along janitor closet, dressing rooms, fire pump room and both storage rooms. All doors are also being replaced. The doors in the rated walls have and 45 min. Assemblies. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62861 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing up to 4 of drywall, electrical fixtures and fuses. This permit is for the 8 s. F. Elementary computer lab. This building received 30" of water. Electrical panels will be inspected by an electrician. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62863 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall and insulation up to 4, electrical fixtures, doors and some plumbing fixtures. This permit pertains to the 1225 s. F. Administration bldg. For the upper school. This building received 20" of water. Electrical panels will be inspected by an electrician. Water closets will also be reinstalled in this permit. This building has 1hr fire barriers. Joints and penetrations need to be sealed. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62851 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall up to 4, electrical fixtures and fuses and some plumbing fixtures. This permit is for the 60 s. F. Novak hall building. This building received 18" of water. Water closets and vanity counters and lavatories are being replaced. Electrical panels will be inspected by an electrician. The breaker will be replaced. The corridor, restrooms, storage and janitors walls are 1 hr rated walls ul: u465 and have 20min label hollow metal doors. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62859 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall up to 4, electrical fixtures and fuses. This permit is for the 14 s. F. Elementary administration building. This building received 32" of water. Electrical panels will be inspected by an electrician. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62864 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall up to 4, electrical fixtures and fuses and some plumbing fixtures. This permit is for the 70 s. F. Performing art building. This building received the 20" of water. 1hr rated wall around janitors closet and storage rooms with 45 min. Doors to be replaced. Exterior walls are also 1hr rated. Electrician will inspect electrical panel. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62867 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes electrical fixtures. This permit is for the 3 s. F. Book room. This building received 20" of water. An electrician will inspect the panel. Replacing wallboard and insulation up to 8. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62868 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall up to 4, electrical fixtures and fuses and some plumbing fixtures. This permit is for the 55 s. F. Koenig hall. This building received 21" of water. The water closets and lavatories will be replaced in the building. An electrician will be inspecting the water panels. This building has an 1hr rated corridor that will be replacing drywall and insulation up to 4. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62866 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing electrical fixtures and fuses. This permit is for the 43 s. F. Courtyard classrooms. The classrooms received 15" of water. Electrical panels will be inspected by an electrician. Client: Dr. Kelly Runnels | Applicant: Harold "chris" Ashy | Permit type: Commercial: remodel | Permit id: 62865 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall up to 4, electrical fixtures and fuses and some plumbing fixtures. This permit is for 96 s. F. Elementary #1 building. This building received 30" of water. Electrical panels will be inspected by an electrician. Will reinstall water closets. There are 1hr rated corridors in this building. All doors are being replaced. Client: Dr. Kelly Runnels | Applicant: Harold "chris" Ashy | Permit type: Commercial: remodel | Permit id: 62862 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing drywall up to 4, electrical fixtures and fuses and some plumbing fixtures. This permit pertains to the 11,2 s. F. Gymnasium. This building received 18" of water. Electrical panels will be inspected by an electrician. This building has 1hr rated fire walls. Joints and penetrations need to be sealed. Doors in fire wall need to be rated. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62858 | |||||
SCORE 84 Flood damage renovations to existing school buildings. Scope of work includes replacing electrical fixtures. This permit is for the 14 s. F. High school portable building. This building received 12" of water. Electrical panels will be inspected by an electrician. Client: Dr. Kelly Runnels | Applicant: Harold Ashy | Permit type: Commercial: remodel | Permit id: 62860 |