Permit for the erection of an attached structure ( 414" ft high) ; roof deck accessed by a pilot house ( containing stairs and landing only) and bay windows at front for a vacant commercial space at first floor and two(2) family household living from second floor thru forth floors.. Size and location as shown in the application. Date: November 10, 2016Client: Unique Project Management | Applicant: Ronald Patterson, Esq. | Permit type: Appeal | Permit status: Continued | Permit id: 29207 | |||||
To amend permit #761399 to revise the size of the sidewall footing as shown in approved plans. Date: May 12, 2017Permit type: Administrative permit | Permit status: Active | Completion date: September 8, 2017 | Permit id: 779398 | |||||
SCORE 100 For the installation of a fire suppression system in accordance with nfpa 2007, standard 13, 13r, & 14 to include a 4-inch diameter standpipe system, a 2-inch diameter service line and a 2. 5-inch diameter backflow prevention assembly. Date: October 20, 2017 Contractor: B. M. Consulting Services IncPermit type: Suppression permit | Permit status: Active | Completion date: November 16, 2017 | Permit id: 789105 | |||||
SCORE 93 New construction: interior plumbing;(4) story mixed-use structure with roof deck to be used as a vacant commercial space on the first floor basement and two (2) dwelling units above; 11 toilets,11 vanities,8 tubs,4 kitchen sinks and 4 laundry - the installation will comply with the philadephia plubming code 2004 Date: October 10, 2017 Contractor: Oleg KapkanovPermit type: Plumbing permit | Permit status: Active | Completion date: November 10, 2017 | Permit id: 799401 | |||||
SCORE 93 Install 5" lateral,curb trap,fai and 1" water service pa20171923796 (multi family)"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: July 13, 2017 Contractor: Oleg KapkanovPermit type: Plumbing permit | Permit status: Completed | Completion date: August 2, 2017 | Permit id: 799413 | |||||
SCORE 100 Complete new wiring switches, recepts, lights, smoke co detectors, 600amp service complete with grounding panels and meters as per 2008 nec (cc district) install fire alarm system as per nfpa72 Date: October 17, 2017 Contractor: Abraham BuyagPermit type: Electrical permit | Permit status: Active | Completion date: October 17, 2017 | Permit id: 807492 | |||||
For the erection of an attached structure with roof deck and pilot house for a vacant commercial space at first floor and two(2) family household living from second floor thru forth floors. Size and location as shown in the application. Date: February 17, 2017Permit type: Zoning/use permit | Permit status: Completed | Completion date: February 17, 2017 | Permit id: 733078 | |||||
For the erection of a four (4) story mixed-use structure with roof deck to be used as a vacant commercial space on the first floor basement and two (2) dwelling units above. Building shall be fully sprinklered with npfa 13. Separate permits required for mechanical, electrical, plumbing, and fire suppression systems. Date: April 11, 2017Permit type: New construction permit | Permit status: Active | Completion date: November 24, 2017 | Permit id: 761399 | |||||
SCORE 99 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Install 3 hvac-sfd Date: September 21, 2017 Contractor: Full Service Investment LlcPermit type: Mechanical permit | Permit status: Active | Completion date: November 7, 2017 | Permit id: 818208 |