Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 84 Complete demo. Of exist. Attached one (1) story masonry bearing wall & structural steel & wood frame construction via hand held tools & equipment only per approved site safety demolition plan & all applicable provisions of the philadelphia code. A covered walkway or sidewalk closure shall be reqd w in 3 ft. Of bldg. Facade @ streets per the phila. Bldg. Code sec. 3306; separate permit from l+i & or streets dept. May be required. Date: June 29, 2017 Contractor: Rjr Group Inc Permit type: Demolition permit | Permit status: Completed | Completion date: September 13, 2017 | Permit id: 783467 | |||||
For the erection of an addition with a roof deck accessed by a pilot house (to enclose access stairs only) above an existing attached structure, size and location as shown on plan application. For use as single-family household living. Date: February 27, 2017 Permit type: Zoning/use permit | Permit status: Completed | Completion date: May 5, 2017 | Permit id: 758419 | |||||
SCORE 99 Install a 1" water service combo,curb trap, all drain lines, all domestic water lines and hot water heater(sfd)pa20172993178 the installation will comply with the philadelphia plumbing code 2004 "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: November 3, 2017 Contractor: Earl D Jay Permit type: Plumbing permit | Permit status: Active | Completion date: November 30, 2017 | Permit id: 827257 | |||||
SCORE 93 Seal lateral and shut off pa201705053 self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: May 2, 2017 Contractor: Reed St Builders Llc Permit type: Plumbing permit | Permit status: Completed | Completion date: July 7, 2017 | Permit id: 778435 | |||||
SCORE 89 Installation of a fire sprinkler system in accordance w nfpa 13d standards. Date: October 19, 2017 Contractor: Aqueduct Fire Protection Permit type: Suppression permit | Permit status: Active | Completion date: November 9, 2017 | Permit id: 817493 | |||||
SCORE 93 New construction single family dwelling as per plans Date: September 1, 2017 Contractor: Reed St Builders Llc Permit type: New construction permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 783744 | |||||
To correct permit language of previously issued ap#758419, due to l&i error for the erection of an attached structure with a roof deck accessed by a pilot house (to enclose access stairs only), size and location as shown on plan application. For use as single-family household living. Date: August 31, 2017 Permit type: Zoning/use permit | Permit status: Completed | Completion date: November 22, 2017 | Permit id: 813118 | |||||
SCORE 100 New 200am service,lighting,receptacles,switches,hardwired smoke detectors,phone,catv wiring per 2008 nec (sfd) Date: October 6, 2017 Contractor: Fred Dinardo Jr Permit type: Electrical permit | Permit status: Active | Completion date: October 6, 2017 | Permit id: 822341 | |||||
SCORE 100 Install (1) hvac system with ductwork. (sfd) Date: October 6, 2017 Contractor: Fred Dinardo Jr Permit type: Mechanical permit | Permit status: Active | Completion date: November 29, 2017 | Permit id: 822391 | |||||
For the lot adjustment to create two (2) new lots ("parcel a" and "parcel b" on plans) from one (1) existing lot (1509-11 s franklin st), size and location as shown on plan application. Date: January 31, 2017 Permit type: Zoning permit | Permit status: Completed | Completion date: May 5, 2017 | Permit id: 726049 |