Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning permit Date: April 6, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 679111 | |||||
Demolition permit Date: April 29, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 682240 | |||||
Alteration permit Date: December 12, 2012 Client: Hanna East Llc | Permit status: Completed | Permit id: 443224 | |||||
Plumbing permit Date: April 4, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 681100 | |||||
Zoning/use permit Date: May 12, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 684513 | |||||
Alteration permit Date: March 27, 2013 Client: Hanna East Llc | Permit status: Expired | Permit id: 451608 | |||||
Zoning/use permit Date: May 12, 2016 Client: Bey Henry Bey Marilyn | Permit status: Completed | Permit id: 689670 | |||||
On 8/24/2016, the department of licenses and inspections issued a notice of refusal for application #705904. Date: September 23, 2016 Client: Bey Henry Bey Marilyn | Applicant: Yao Chang Huang | Permit type: Appeal | Permit id: 28906 | |||||
Zoning/use permit Date: April 29, 2016 Client: Bey Henry Bey Marilyn | Permit status: Completed | Permit id: 684605 | |||||
Zoning use permit Date: April 29, 2016 Client: Bey Henry Bey Marilyn | Permit status: Completed | Permit id: 684605 | |||||
SCORE 86 Install 400amp service and ground,150amp per apt. Meter,100amp for house, wiring throughout with lights,switches,outlets,low voltage wiring of phone and cable and battery backup,smoke co as per 2008 nec (east district) Date: August 10, 2017 Contractor: Sigma Electric Group Inc Permit type: Electrical permit | Permit status: Active | Completion date: August 10, 2017 | Permit id: 799460 | |||||
SCORE 100 Install (4) heat pumps with ductwork. (multi-family) Date: June 27, 2017 Contractor: Fresh Air Services Inc Permit type: Mechanical permit | Permit status: Active | Completion date: August 28, 2017 | Permit id: 794817 | |||||
SCORE 86 Installation 5" lateral house trap fresh inlet. 3 4" water distribution Date: August 29, 2017 Contractor: Anc Plumbing Inc Permit type: Plumbing permit | Permit status: Completed | Completion date: September 1, 2017 | Permit id: 812321 | |||||
SCORE 89 Installation of an automatic sprinkler system in accordance with nfpa 13 with a new 2" backflow system and 2" fire service as per plan. Date: July 14, 2017 Contractor: Aqueduct Fire Protection Permit type: Suppression permit | Permit status: Active | Completion date: July 24, 2017 | Permit id: 785581 | |||||
SCORE 100 New construction of a three (3) story, four (4) family dwelling with two (2) roof decks and two (2) pilot houses (access to roof decks only) as per approved plans and bbs variance 29958. Building to be fully sprinklered per nfpa 13. Separate permits required for mep & fire suppression work Date: March 28, 2017 Contractor: Fresh Air Services Inc Permit type: New construction permit | Permit status: Active | Completion date: November 1, 2017 | Permit id: 705909 | |||||
SCORE 100 New construction: interior plumbing: three (3) story, four (4) family dwelling; roof deck; 6 water closets, 6 lavy sinks, 4 bath tubs, 2 showers, 4 laundries, 4 kitchen sinks, 4 dishwashers, 2 ose bibs, 3 floor drains, 7 hub drains, 2duplex sewage pump systems, liberty 1102 le41m & 4 hot water heaters - the installation will comply with the philadelphia plumbing code 2004 Date: August 4, 2017 Contractor: Atis Plumbing And Hvac Inc Permit type: Plumbing permit | Permit status: Active | Completion date: August 28, 2017 | Permit id: 799920 | |||||
SCORE 100 For documentation of complete demolition of existing attached building; size & location as shown in application. Use registration required prior to occupancy or any other development. See zoning use registration permit# 682237 for approved site plan. Date: April 29, 2016 Contractor: Gama Wrecking Inc Permit type: Zoning/use permit | Permit status: Completed | Completion date: April 29, 2016 | Permit id: 684605 | |||||
Zoning permit Date: April 6, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 679111 | |||||
Alteration permit Date: December 12, 2012 Client: Hanna East Llc | Permit status: Completed | Permit id: 443224 | |||||
Demolition permit Date: April 29, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 682240 | |||||
Zoning use permit Date: April 29, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 682237 | |||||
Plumbing permit Date: February 1, 2016 Client: Hanna East Llc | Permit status: Completed | Permit id: 667149 | |||||
Alteration permit Date: March 27, 2013 Client: Hanna East Llc | Permit status: Expired | Permit id: 451608 | |||||
Zoning use permit Date: May 12, 2016 Client: Bey Henry Bey Marilyn | Permit status: Completed | Permit id: 689670 | |||||
On 8 24 2016, the department of licenses and inspections issued a notice of refusal for application #705904. Date: September 23, 2016 Client: Bey Henry Bey Marilyn | Applicant: Yao Chang Huang | Permit type: Appeal | Permit status: Approved | Completion date: December 19, 2016 | Permit id: 28906 | |||||
SCORE 86 Install new 5" lat house trap fai 4-3 4" water distr Date: August 29, 2017 Contractor: Anc Plumbing Inc Permit type: Plumbing permit | Permit status: Completed | Completion date: August 31, 2017 | Permit id: 798846 | |||||
SCORE 100 New construction:(3) story, four (4) family dwelling; roof deck - the installation will comply with the philadelphia plumbing code 2004 Date: August 4, 2017 Contractor: Atis Plumbing And Hvac Inc Permit type: Plumbing permit | Permit status: Active | Completion date: August 28, 2017 | Permit id: 799150 | |||||
SCORE 86 Install 400amp service and ground,150amp per apt. Meter,100amp for house, wiring throughout with lights,switches,outlets,low voltage wiring of phone and cable and battery backup,smoke co as per 2008 nec (east district) Date: August 10, 2017 Contractor: Sigma Electric Group Inc Permit type: Electrical permit | Permit status: Active | Completion date: August 10, 2017 | Permit id: 799459 | |||||
SCORE 100 Install (4) heat pumps with ductwork. (multi-family) Date: June 27, 2017 Contractor: Fresh Air Services Inc Permit type: Mechanical permit | Permit status: Active | Completion date: August 28, 2017 | Permit id: 794816 | |||||
SCORE 89 Installation of an automatic sprinkler system in accordance with nfpa 13 with a new 2" backflow system and 2" fire service as per plan. Date: June 6, 2017 Contractor: Aqueduct Fire Protection Permit type: Suppression permit | Permit status: Active | Completion date: July 24, 2017 | Permit id: 785583 | |||||
SCORE 100 For documentation of complete demolition of existing attached building; size & location as shown in application. Use registration required prior to occupancy or any other development. See zoning use registration permit# 682237 for approved site plan. Date: April 29, 2016 Contractor: Gama Wrecking Inc Permit type: Zoning/use permit | Permit status: Completed | Completion date: April 29, 2016 | Permit id: 684604 | |||||
SCORE 100 New construction of a three (3) story, four (4) family dwelling with two (2) roof decks and two (2) pilot houses (access to roof decks only) as per approved plans and bbs variance 28906. Building to be fully sprinklered per nfpa 13 separate permits required for mep & fire suppression work Date: March 28, 2017 Contractor: Fresh Air Services Inc Permit type: New construction permit | Permit status: Active | Completion date: August 16, 2017 | Permit id: 705904 |