Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Construct alterations to existing school (leschi elementary school) for new geothermal well field at playground area, per plan. Date: November 25, 2015 Value: $850,000 Applicant: Salisbury, Erik | Permit type: Construction | Permit status: Reviews completed | Current use: Institutional | Permit id: 6503858 | |||||
Re-roof of existing leschi elementary school (entire roof -- 62,0 sf), subject to field inspection Date: October 1, 2015 Value: $900,000 Applicant: Hagen, Ellen | Permit type: Construction | Permit status: Permit issued | Current use: Commercial | Permit id: 6489270 | |||||
SCORE 99 Construct alterations to existing school (leschi elementary school) for new geothermal well field at playground area, per plan. Applicant: Salisbury, Erik | Permit type: Construction | Permit status: Permit issued | Expiration date: July 21, 2017 | Current use: Institutional | Permit id: 6503858 | |||||
SCORE 95 Make interior non-structural alterations to exisitng school library, all per subject to field inspection. Stfi Applicant: Queen, Shawn | Permit type: Construction | Permit status: Permit closed | Completion date: April 5, 2007 | Expiration date: August 14, 2007 | Current use: Commercial | Permit id: 6088261 | |||||
SCORE 95 Disconnect power to (2) 25hp motors and re-connect once new motors are installled Date: July 26, 2016 Contractor: Seahurst Electric Incorporated Permit type: Electrical | Permit status: Permit issued | Expiration date: July 26, 2017 | Current use: Institutional | Permit id: 6548117 | |||||
SCORE 100 Low voltage hvac controls Date: June 8, 2016 Contractor: Foy Group Corporation Permit type: Electrical | Permit status: Permit closed | Completion date: September 2, 2016 | Expiration date: June 8, 2017 | Current use: Commercial | Permit id: 6539310 | |||||
SCORE 79 Install 75kva trans. Via panel pp5, install 225 amp pdp via 75 kva trans, install 2 amp sub feed to new portable classroom. Date: May 18, 2016 Contractor: Bramlett Andrew Permit type: Electrical | Permit status: Permit issued | Expiration date: May 18, 2017 | Current use: Institutional | Permit id: 6535577 | |||||
SCORE 79 Add 3 new fire alarm devices; 1 smoke, 1 pull station, and 1 horn/strobes. [leschi elementary school; portable p1] Date: April 27, 2016 Contractor: Bark Roger Permit type: Electrical | Permit status: Permit issued | Expiration date: April 27, 2017 | Current use: Institutional | Permit id: 6531694 | |||||
SCORE 95 Cooling tower demo, addition of subterranean geothermal vault, select pump replacement Permit type: Electrical | Permit status: Permit issued | Expiration date: January 4, 2017 | Current use: Institutional | Permit id: 6509083 | |||||
SCORE 59 Add [4] outlets to wall, [2] exit signs [rm 110] Date: July 6, 2015 Contractor: Seattle Public School Permit type: Electrical | Permit status: Permit closed | Completion date: September 1, 2015 | Expiration date: July 6, 2016 | Current use: Commercial | Permit id: 6481327 | |||||
SCORE 99 Library tenant improvement, ehs job no. 66030 Date: July 11, 2006 Contractor: E H S Llc Permit type: Electrical | Permit status: Permit finaled | Completion date: September 6, 2006 | Expiration date: July 11, 2007 | Current use: Commercial | Permit id: 6105202 | |||||
SCORE 95 New heat pumps, cooling unit in mdf room and exhaust fans and re-inforce existing support structure for mechanical equipment in attic of leschi elementary school, per plan. Applicant: Maman, Laura | Permit type: Mechanical | Permit status: Permit closed | Completion date: December 5, 2012 | Expiration date: December 29, 2012 | Current use: Institutional | Permit id: 6274795 | |||||
SCORE 84 8 8 2014 - cancelled customer log #14-683 wireless access point installation (poe) Date: July 29, 2014 Contractor: Ednetics Inc Permit type: Electrical | Permit status: Permit issued | Expiration date: July 29, 2015 | Current use: Institutional | Permit id: 6429361 | |||||
SCORE 70 Add [4] outlets to wall, [2] exit signs [rm 110] Date: July 6, 2015 Contractor: Seattle Public School, Permit type: Electrical | Permit status: Permit closed | Completion date: September 1, 2015 | Expiration date: July 6, 2016 | Current use: Commercial | Permit id: 6481327 | |||||
SCORE 82 Install 75kva trans. Via panel pp5, install 225 amp "pdp" via 75 kva trans, install 2 amp sub feed to new portable classroom. Date: May 18, 2016 Contractor: Bramlett, Andrew Permit type: Electrical | Permit status: Permit issued | Expiration date: May 18, 2017 | Current use: Institutional | Permit id: 6535577 | |||||
SCORE 99 Construct alterations to existing school (leschi elementary school) for new geothermal well field at playground area, per plan. Applicant: Salisbury, Erik | Permit type: Construction | Permit status: Permit issued | Expiration date: July 21, 2017 | Current use: Institutional | Permit id: 6503858 | |||||
SCORE 95 Install (2) non-illum ground signs with manualally changing reader boards for "leschi elementary school", allowed by departure. Date: November 19, 2013 Contractor: Heath Northwest Applicant: Heath Northwest | Permit type: Sign/billboard/awning | Permit status: Permit closed | Completion date: May 8, 2014 | Expiration date: May 19, 2015 | Current use: Commercial | Permit id: 6391906 | |||||
SCORE 100 Replace storm pipe. (assoc. Bldg permit no. 6503858). 8/25/16 ar revise permit from repair to alteration Date: August 10, 2016 Contractor: Iliad Inc Applicant: Iliad Inc | Permit type: Side sewer | Permit status: Permit closed | Completion date: September 12, 2016 | Expiration date: February 10, 2018 | Current use: Industrial | Permit id: 6550730 | |||||
SCORE 95 Install and geothermal well field in the play asphalt court to connect to the existing mechanical heat pumps Contractor: Seattle Public Schools Applicant: Salisbury, Erik | Permit type: Site development | Permit status: Information collected | Current use: Institutional | Permit id: 6501436 | |||||
SCORE 99 Construct alterations to existing school (leschi elementary school) for new geothermal well field at playground area, per plan. Applicant: Salisbury, Erik | Permit type: Construction | Permit status: Permit closed | Completion date: July 26, 2017 | Expiration date: July 21, 2017 | Current use: Institutional | Permit id: 6503858 | |||||
SCORE 82 4 11 2017 - cancelled customer log #17-463add 3 new fire alarm devices; 1 smoke, 1 pull station, and 1 horn strobes. [leschi elementary school; portable p1] Date: April 27, 2016 Contractor: Bark, Roger Permit type: Electrical | Permit status: Permit issued | Expiration date: April 27, 2017 | Current use: Institutional | Permit id: 6531694 | |||||
Seismic upgrades to 1) install brick veneer ties at designate areas of exterior wall; 2) anchor bearing walls to roof diaphram Applicant: Stovin, Stuart | Permit type: Construction | Permit status: Initial information colle | Current use: Institutional | Permit id: 6615563 | |||||
SCORE 86 Electrical support of mechanical upgrades including new electrical panel for leschi elementary Permit type: Electrical | Permit status: Permit closed | Completion date: October 31, 2011 | Expiration date: October 17, 2012 | Current use: Commercial | Permit id: 6279362 | |||||
SCORE 86 Cancel per customer log 11-763disconnect reconnect mechanical equipment - replace 200a panel board Date: August 4, 2011 Contractor: Western Pacific Electric Llc Permit type: Electrical | Permit status: Permit issued | Expiration date: August 4, 2012 | Current use: Commercial | Permit id: 6291472 | |||||
SCORE 95 Make interior non-structural alterations to exisitng school library, all per subject to field inspection. Stfi Applicant: Queen, Shawn | Permit type: Construction | Permit status: Permit closed | Completion date: April 5, 2007 | Expiration date: August 14, 2007 | Current use: Commercial | Permit id: 6088261 | |||||
SCORE 95 125a single phase feeder to portable calssroom via existing 200a 208v pdp panel Date: July 17, 2017 Contractor: Seattle School District Permit type: Electrical | Permit status: Permit issued | Expiration date: July 17, 2018 | Current use: Institutional | Permit id: 6608292 | |||||
SCORE 95 New heat pumps, cooling unit in mdf room and exhaust fans and re-inforce existing support structure for mechanical equipment in attic of leschi elementary school, per plan. Applicant: Maman, Laura | Permit type: Mechanical | Permit status: Permit closed | Completion date: December 5, 2012 | Expiration date: December 29, 2012 | Current use: Institutional | Permit id: 6274795 | |||||
SCORE 95 6 20 2017- cancelled customer log #17-848cooling tower demo, addition of subterranean geothermal vault, select pump replacement Permit type: Electrical | Permit status: Permit issued | Expiration date: January 4, 2017 | Current use: Institutional | Permit id: 6509083 | |||||
SCORE 96 Low voltage controls Date: June 29, 2011 Contractor: Wpcs Intl Inc Sea Op Permit type: Electrical | Permit status: Permit closed | Completion date: February 6, 2013 | Expiration date: June 28, 2012 | Current use: Commercial | Permit id: 6287742 |