ACTIVITY
PERMITS VALUATION
Get several free quotes from best contractors in your area.
| Content | Date | Cost | Contractor Rank | Address | Contractor |
|---|---|---|---|---|---|
Zoning admin review Date: March 16, 2016Client: Chan Xiaoxian L | Permit status: Completed | Permit id: 669298 | |||||
Zoning/use permit Date: January 12, 2016Client: Chan Xiaoxian L | Permit status: Completed | Permit id: 648764 | |||||
Zoning use permit Date: January 12, 2016Client: Chan Xiaoxian L | Permit status: Completed | Permit id: 648764 | |||||
For the complete demolition of the existing structure and for the erection of an attached structure with a roof deck at the third floor rear (no pilot house). Size and location as shown on plans application. For use as single family household living with one (1) interior accessory parking space accessed at the front of the properly. See a p no 607664. Date: January 12, 2016Permit type: Zoning/use permit | Permit status: Completed | Completion date: January 12, 2016 | Permit id: 648764 | |||||
For the construction of a two-story addition on top of an existing one-story structure and for the replacement of front and back exterior walls, as per approved plans. A covered walkway or sidewalk closure shall be required within 8 feet of building facade in accordance with section 3306 of the ibc. Date: April 27, 2017Permit type: Addition permit | Permit status: Active | Completion date: October 24, 2017 | Permit id: 699710 | |||||
For the administrative review of a p no 648764, cal no 25752, to revise the height of the roof from 32-4" to 38-0". Make the 3rd floor roof deck smaller and increase the size of the living area on the 3rd floor (no change in footprint of the structure or previously approved parking). Date: March 16, 2016Permit type: Zoning admin review | Permit status: Completed | Completion date: March 23, 2016 | Permit id: 669298 | |||||
SCORE 100 4 wc,4 lavs,3 bath tubs,1 shower stall,laundry and kitchen sink (sfd)the installation will comply with the philadelphia plumbing code 2004 Date: September 28, 2017 Contractor: Jamal MechanicalPermit type: Plumbing permit | Permit status: Active | Completion date: October 18, 2017 | Permit id: 820108 | |||||
SCORE 100 For the installation of a fire suppression system in accordance with nfpa 2007, standard 13d to include a combined 1-inch diameter service line. Date: August 11, 2017 Contractor: B. M. Consulting Services IncPermit type: Suppression permit | Permit status: Active | Completion date: September 21, 2017 | Permit id: 799417 | |||||
SCORE 100 New 200a service with new meter socket and main panel. Complete wiring of property of all switches, outlets, lighting, smoke detectors and cable and phone outlets.... In accordance with 2008 nec for a one family building Date: October 4, 2017 Contractor: Tech Electric Services IncPermit type: Electrical permit | Permit status: Active | Completion date: October 4, 2017 | Permit id: 820290 | |||||
SCORE 100 New sewer line main to bldg,new 1" combined line domestic line main to bldeg and new fai pa20172492590(sfd) "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: September 7, 2017 Contractor: B. M. Consulting Services IncPermit type: Plumbing permit | Permit status: Completed | Completion date: September 27, 2017 | Permit id: 814301 | |||||
To amend a p no 648764, cal no 25752 to document that the existing structure will be partially demolished and an addition will be erected (as opposed to complete demolition and new construction). Approved construction will be same height area as that approved in a p no 669298. This permit is to amend a p no 648764 in conjunction with a p no 669298. Date: November 4, 2016Permit type: Zoning admin review | Permit status: Completed | Completion date: November 4, 2016 | Permit id: 731142 |