Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Date: August 4, 2004 Permit status: Closed | Permit id: 04-03641 | |||||
Comment date: mon aug 02 00:00: edt 2004 - curtis deck, 6 sq ft. Around a pool. Lcs; comment date: wed aug 04 00:00: edt 2004 - building sa Value: $2,200 Client: Curtis Pool Deck | Permit type: Res: accessory structure | Permit status: Closed | Current use: Residential | Permit id: 04-03641 | Parcel: 31458 | |||||
SCORE 100 Curtis, robert Date: July 5, 2011 Contractor: Gentry Heating Inc Client: Curtis, Robert | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-06068 | Parcel: 553168 | |||||
Curtis deck, 6 sq ft. Around a pool. Lcs; building safety comments: free-standing deck construction was field evaluated as work-in-progress. Add joist hangers and/or ledger strips at ends of joists. Install lateral knee braces using 4x4 diagonal braces bolted at each end with 5/8" hot-dipped galvanized bolts. Add dropped double 2x8 beams at midspan of 2x6 floor joists to reduce the span of the joists. Construct guardrails around the perimeter of the deck and adjust height to provide a minimum barrier height of 4-feet around the pool area. The gate enclosure to the pool area shall be self-closing and self-latching. For building inspections contact gary stamey at redacted phone number. Permit type: Res: accessory structure | Permit status: Closed | Permit id: 04-03641 | Parcel: 31458 | |||||
October 22, 20 2:45:01 pm jfortner. Installing 100,0 btu oil furnace. Reconnect electrical. Rec via fax. To schedule inspection call (828)redacted phone number; jlf Permit type: Permits - historical | Permit status: Closed | Permit id: 10-06068 | Parcel: 553168 | |||||
Curtis deck, 6 sq ft. Around a pool. Lcs; comment date: wed aug 04 00:00: edt 2004 - building sa Date: August 4, 2004 Value: $2,200 Client: Curtis Pool Deck | Permit type: Res: accessory structure | Permit status: Closed | Current use: Residential | Permit id: 04-03641 | Parcel: 31458 | |||||
Residential Date: August 4, 2004 Value: $2,200 Permit status: Closed | Permit id: 04-03641 | |||||
October 22, 20 2:45:01 pm jfortner. Installing 100,0 btu oil furnace. Reconnect electrical. Rec via fax. To schedule inspection call (828)redacted phone number; jlf Date: July 5, 2011 Permit type: Permits - historical | Permit status: Closed | Permit id: 10-06068 | Parcel: 553168 | |||||
Curtis deck, 6 sq ft. Around a pool. Lcs; building safety comments: free-standing deck construction was field evaluated as work-in-progress. Add joist hangers and or ledger strips at ends of joists. Install lateral knee braces using 4x4 diagonal braces bolted at each end with 5 8" hot-dipped galvanized bolts. Add dropped double 2x8 beams at midspan of 2x6 floor joists to reduce the span of the joists. Construct guardrails around the perimeter of the deck and adjust height to provide a minimum barrier height of 4-feet around the pool area. The gate enclosure to the pool area shall be self-closing and self-latching. For building inspections contact gary stamey at redacted phone number. Date: August 4, 2004 Permit type: Res: accessory structure | Permit status: Closed | Permit id: 04-03641 | Parcel: 31458 |