Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 Remodel on three dorms. Adding microwave circuit, refridge circuit, countertop circuit,electric range circuit. Changing light fixtures adding a track light. Date: July 1, 2009 Contractor: Holmes Electric Company Permit type: Electrical | Permit status: Permit closed | Completion date: August 11, 2009 | Expiration date: July 1, 2010 | Current use: Commercial | Permit id: 6220312 | |||||
SCORE 95 Addition of (3) smoke detectors & relocation of (1) pull station Date: July 16, 2008 Contractor: Absco Alarms Incorporated Permit type: Electrical | Permit status: Permit closed | Completion date: August 25, 2008 | Expiration date: July 16, 2009 | Current use: Single family / duplex | Permit id: 6187938 | |||||
SCORE 95 Provide access control for xavier hall se stair. Date: July 9, 2008 Contractor: Absco Alarms Incorporated Permit type: Electrical | Permit status: Permit closed | Completion date: August 25, 2008 | Expiration date: July 9, 2009 | Current use: Institutional | Permit id: 6187149 | |||||
SCORE 100 Install 150amp circuit for shunt trip disconnect for elevator. 1-100amp fused disconnect 1-30amp panel in elevator room 1-20amp lockable disconnect for elevator cab. 2-gfci recpts. 3-fixtures. 1-20amp circuit for fire damper 1-20amp circuit for chust fan with control relay Date: April 4, 2008 Contractor: Holmes Electric Company Permit type: Electrical | Permit status: Permit closed | Completion date: August 21, 2008 | Expiration date: April 4, 2009 | Current use: Commercial | Permit id: 6176295 | |||||
SCORE 56 Remove old lamp fixtures and replace with (26) 3 lamp t-8 fixtures. Relocate (4) existing smoke alarms into new dropped ceiling. Date: February 14, 2008 Contractor: Miley Lee Permit type: Electrical | Permit status: Permit closed | Completion date: May 12, 2009 | Expiration date: February 14, 2009 | Current use: Institutional | Permit id: 6170392 | |||||
SCORE 95 Provide safety upgrades for xavier hall to accommodate a new elevator & classrooms - fire alarm devices Date: July 9, 2007 Contractor: Absco Alarms Incorporated Permit type: Electrical | Permit status: Permit finaled | Completion date: September 12, 2007 | Expiration date: July 9, 2008 | Current use: Commercial | Permit id: 6144126 | |||||
SCORE 95 Transition from a wireless security system to a hardwired security system. Date: August 30, 2006 Contractor: Absco Alarms Incorporated Permit type: Electrical | Permit status: Permit finaled | Completion date: January 3, 2007 | Expiration date: August 30, 2007 | Current use: Institutional | Permit id: 6111056 | |||||
Add (16) below grid ceiling sprinkler heads with new branch line piping per plan Date: January 10, 2008 Value: $4,900 Applicant: Paris, Steve | Permit type: Mechanical | Permit status: Permit issued | Expiration date: July 10, 2009 | Current use: Commercial | Permit id: 6165302 | |||||
SCORE 56 Remove old lamp fixtures and replace with (26) 3 lamp t-8 fixtures. Relocate (4) existing smoke alarms into new dropped ceiling. 1 9 09 qn - about to expire letter sent. Date: February 14, 2008 Contractor: Miley, Lee Permit type: Electrical | Permit status: Permit closed | Completion date: May 12, 2009 | Expiration date: February 14, 2009 | Current use: Institutional | Permit id: 6170392 | |||||
SCORE 100 Electrical ti of basement, includes classromms, kitchen, study area and bathrooms; relocation and addition of feeders. 6/29/07 mvc: address correction from 1111 e madison st. Permit type: Electrical | Permit status: Permit finaled | Completion date: September 12, 2007 | Expiration date: July 17, 2008 | Current use: Institutional | Permit id: 6143818 |