SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 14-6 : additional scope of work at same area 26l. Valuation increased from 10k to to 135k and associated fees re-assessed on parent permit. Date: August 26, 2014 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 14rev-00500 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Install (3) tec-90s, (3) step down transformers, (1) absorber motors, daq cabinet, chiller and disconnect in 2cl dyno lab. Install new step down transformer after the meter and stand at ch 25m. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 14000-00816 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Building 26l: install new equipment in dyno lab, including two (2) 4-square machines Permit type: Project - building permit | Permit status: Permit issued | Permit id: 14000-00629 | |||||
SCORE 92 Date: February 21, 2014 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 14rev-00108 | |||||
SCORE 92 Permit type: Project - building permit | Permit status: Permit issued | Permit id: 14000-00253 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Installation of bridge crane system in 26m with associated electrical equipment. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 14000-00247 | |||||
SCORE 92 Date: January 22, 2014 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 14rev-00040 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Tesla: install interior roll up door, new step transformers located after the meter, new thermal chambers, new vibration tables, new uninterupted power supplies Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-03142 | |||||
SCORE 92 Date: December 20, 2013 Contractor: Tesla Motors Inc Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-03397 | |||||
SCORE 92 Date: December 20, 2013 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 13rev-00789 | |||||
SCORE 92 Date: December 20, 2013 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 13rev-00788 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 13000-02636: post will no longer be embeded in concrete, so revised calcs and detail provided to show post is anchorted to footing Date: December 13, 2013 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 13rev-00774 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Tesla upper; tenant improvements(elec only)includes install lighting and outlets and change door swing. Date: December 13, 2013 Contractor: Tesla Motors Inc Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-03287 | |||||
SCORE 92 Date: November 22, 2013 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 13rev-00732 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Lab equipment in cellcharacterization lab on 26l: install chambers, themal enclosures, new double door and recepticles. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02869 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Testing equipment in power eletronics lab 26m: install temperature chambers, transformers, te- chamber oven, ac source and low pony wall. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02870 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 26 lower; install transformers on racks and associated electrical work. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02990 | |||||
SCORE 92 Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02989 | |||||
SCORE 92 Date: November 13, 2013 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 13rev-00706 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 26 middle; install (2) transformers and associated electrical work. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02952 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Commercial: install 33 exterior evses including installation of 150kva transformer in landscaping Date: October 1, 2013 Contractor: Tesla Motors Inc Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02636 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Tesla: installation of equipment and exhaust fan on lower floor; scope of work includes equipment installation previously issued under 11-3244 and 11-1063 which were never finaled per meeting with bud, peter and fire dept. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02744 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Lab equipmeent includes wall mounted charging station associated structural and electrical. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02843 | |||||
SCORE 92 Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02570 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Install full height walls to create new work space, metal fabrication equipment (cng press, brake hydraulic shear) and lighting in sheet metal shop approx 2138 sq ft Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02638 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Bldg 26l install (n) equipment: dyono #6, tec 905 transformers, water chiller, electrocal disconnect and battery system. Install (n) interior door. Date: May 8, 2012 Contractor: Tesla Motors Inc Permit type: Project - building permit | Permit status: Permit issued | Permit id: 12000-01054 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Bldg 24l- equipment expansion for phase 2: (1) fume hood, (2) glove boxes & dry room equipment for cell research Date: March 16, 2012 Contractor: Tesla Motors Inc Permit type: Project - building permit | Permit status: Permit issued | Permit id: 12000-00588 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 (ref permit #11-1063) building 26l: electrical revisions to thermal chambers. Date: April 11, 2012 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 12rev-00207 | |||||
SCORE 92 26-M / 35 Deer Creek Rd, Bldg 26 M, Palo Alto, Ca 94304 (ref permit #11-3244) bldg 26l revision to environmental chambers, electrical alterations and additional chamger chiller and new transformer. Date: April 11, 2012 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 12rev-00206 | |||||
SCORE 92 26-L / 35 Deer Creek Rd, Bldg 26 L, Palo Alto, Ca 94304 (ref permit #11-226) electrical additions to thermal vehicle chamber. Date: April 4, 2012 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 12rev-00197 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Building 24, tesla: install a 24m-nvh vehicle chamber and lift with associated electrical and mechanical. Date: March 6, 2012 Contractor: Tesla Motors Inc Permit type: Project - building permit | Permit status: Permit issued | Permit id: 12000-00501 | |||||
SCORE 92 26-M / 35 Deer Creek Rd, Bldg 26 M, Palo Alto, Ca 94304 Ref permit #11-3245. Amendments to include architectural, structural & plumbing revisions to bldg 24-l: for the thermal enclosure and (2) fume hoods. Date: February 6, 2012 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 12rev-00064 | |||||
SCORE 92 26-M / 35 Deer Creek Rd, Bldg 26m, Palo Alto, Ca 94304 (ref permit #11-3244) bldg 26l revision to environmental chambers, electrical alterations and additional chamger chiller and new transformer. Date: April 11, 2012 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 12rev-00206 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 Tesla: install (3) tec power supplies, (3) transformers, (2) absorber fans, & (1) new 400amp/480volt panel in dyno lab on second floor. Permit type: Project - building permit | Permit status: Permit issued | Permit id: 13000-02657 | |||||
SCORE 92 26-M / 35 Deer Creek Rd, Bldg 26m, Palo Alto, Ca 94304 Ref permit #11-3245. Amendments to include architectural, structural & plumbing revisions to bldg 24-l: for the thermal enclosure and (2) fume hoods. Date: February 6, 2012 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 12rev-00064 | |||||
SCORE 92 26-L / 35 Deer Creek Rd, Bldg 26l, Palo Alto, Ca 94304 (ref permit #11-226) electrical additions to thermal vehicle chamber. Date: April 4, 2012 Contractor: Tesla Motors Inc Permit type: Building/revision/revision/revision | Permit status: Permit issued | Permit id: 12rev-00197 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Install (3) tec-90s, (3) step down transformers, (1) absorber motors, daq cabinet, chiller and disconnect in 2cl dyno lab. Install new step down transformer after the meter and stand at ch 25m. Permit status: Permit issued | Permit id: 14000-00816 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Building 26l: install new equipment in dyno lab, including two (2) 4-square machines Permit status: Permit issued | Permit id: 14000-00629 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Installation of bridge crane system in 26m with associated electrical equipment. Permit status: Permit issued | Permit id: 14000-00247 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Tesla upper; tenant improvements(elec only)includes install lighting and outlets and change door swing. Date: December 13, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13000-03287 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Tesla: install interior roll up door, new step transformers located after the meter, new thermal chambers, new vibration tables, new uninterupted power supplies Permit status: Permit issued | Permit id: 13000-03142 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 26 lower; install transformers on racks and associated electrical work. Permit status: Permit issued | Permit id: 13000-02990 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Testing equipment in power eletronics lab 26m: install temperature chambers, transformers, te- chamber oven, ac source and low pony wall. Permit status: Permit issued | Permit id: 13000-02870 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Lab equipment in cellcharacterization lab on 26l: install chambers, themal enclosures, new double door and recepticles. Permit status: Permit issued | Permit id: 13000-02869 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Tesla: installation of equipment and exhaust fan on lower floor; scope of work includes equipment installation previously issued under 11-3244 and 11-1063 which were never finaled per meeting with bud, peter and fire dept. Permit status: Permit issued | Permit id: 13000-02744 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Building 26l, tesla: install (n) equipment -haas plasma cutter Permit status: Permit issued | Permit id: 13000-02570 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 14-6 : additional scope of work at same area 26l. Valuation increased from 10k to to 135k and associated fees re-assessed on parent permit. Date: August 26, 2014 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 14rev-00500 | |||||
SCORE 92 Date: August 25, 2014 Contractor: Tesla Motors Inc Permit id: 14rev-00499 | |||||
SCORE 92 Date: February 21, 2014 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 14rev-00108 | |||||
SCORE 92 Permit status: Permit issued | Permit id: 14000-00253 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 13-3142: revised electrical and add new thermal chamber. Date: January 22, 2014 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 14rev-00040 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 13000-02636: post will no longer be embeded in concrete, so revised calcs and detail provided to show post is anchorted to footing Date: December 13, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13rev-00774 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Install charging station on 24m and (6) quad drops on 26l. Date: December 20, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13000-03397 | |||||
SCORE 92 Date: December 20, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13rev-00789 | |||||
SCORE 92 Date: December 20, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13rev-00788 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Commercial: install 33 exterior evses including installation of 150kva transformer in landscaping Date: October 1, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13000-02636 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 13-2636: revised trenching plan and associated changes. Date: November 22, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13rev-00732 | |||||
SCORE 92 Date: November 13, 2013 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 13rev-00706 | |||||
SCORE 92 Permit status: Permit issued | Permit id: 13000-02989 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 26 middle; install (2) transformers and associated electrical work. Permit status: Permit issued | Permit id: 13000-02952 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Lab equipmeent includes wall mounted charging station associated structural and electrical. Permit status: Permit issued | Permit id: 13000-02843 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Tesla: install (3) tec power supplies, (3) transformers, (2) absorber fans, & (1) new 400amp 480volt panel in dyno lab on second floor. Permit status: Permit issued | Permit id: 13000-02657 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Install full height walls to create new work space, metal fabrication equipment (cng press, brake hydraulic shear) and lighting in sheet metal shop approx 2138 sq ft Permit status: Permit issued | Permit id: 13000-02638 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Bldg 26l install (n) equipment: dyono #6, tec 905 transformers, water chiller, electrocal disconnect and battery system. Install (n) interior door. Date: May 8, 2012 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 12000-01054 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Bldg 24l- equipment expansion for phase 2: (1) fume hood, (2) glove boxes & dry room equipment for cell research Date: March 16, 2012 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 12000-00588 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca (ref permit #11-1063) building 26l: electrical revisions to thermal chambers. Date: April 11, 2012 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 12rev-00207 | |||||
SCORE 92 26-M / 35 Deer Creek Rd, Bldg 26m, Palo Alto, Ca 94304 San Diego Ca (ref permit #11-3244) bldg 26l revision to environmental chambers, electrical alterations and additional chamger chiller and new transformer. Date: April 11, 2012 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 12rev-00206 | |||||
SCORE 92 26-L / 35 Deer Creek Rd, Bldg 26l, Palo Alto, Ca 94304 San Diego Ca (ref permit #11-226) electrical additions to thermal vehicle chamber. Date: April 4, 2012 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 12rev-00197 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Building 24, tesla: install a 24m-nvh vehicle chamber and lift with associated electrical and mechanical. Date: March 6, 2012 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 12000-00501 | |||||
SCORE 92 26-M / 35 Deer Creek Rd, Bldg 26m, Palo Alto, Ca 94304 San Diego Ca Ref permit #11-3245. Amendments to include architectural, structural & plumbing revisions to bldg 24-l: for the thermal enclosure and (2) fume hoods. Date: February 6, 2012 Contractor: Tesla Motors Inc Permit status: Permit issued | Permit id: 12rev-00064 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 16-2276: revised plans include trench runs and associated electrical work. Includes new electrical equipment. Date: April 21, 2017 Contractor: Tesla Motors Inc Permit status: In plan check | Permit id: 17rev-00245 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca Installation of tesla power pack, inverter and new switch gear at rear courtyard. Permit status: Permit issued | Permit id: 16000-02276 | |||||
SCORE 92 35 Deer Creek Rd, Palo Alto, Ca 94304 San Diego Ca 16000-02276: revision revised electrical, existing 800amp breaker to remain Date: October 19, 2017 Contractor: Tesla Motors Inc Permit status: Completed | Permit id: 17rev-00678 |